Literature DB >> 8026201

Women are at greater risk than men for malpositioning of the endotracheal tube after emergent intubation.

D E Schwartz1, J A Lieberman, N H Cohen.   

Abstract

OBJECTIVES: To investigate the occurrence of endotracheal tube malpositioning after emergent intubation in critically ill adults and to determine the need for a routine postintubation chest radiography to assess endotracheal tube position.
DESIGN: Prospective study.
SETTING: All adult critical care and acute care units of a 560-bed university teaching hospital. PATIENTS: Study of 297 consecutive intubations (185 intubations in males and 112 intubations in females) in 238 adult patients.
METHODS: Emergent endotracheal intubations were performed by resident physicians with supervision from an intensive care unit (ICU) or anesthesia attending physician or an anesthesia resident. After intubation, proper positioning of the endotracheal tube was verified by the intubating physician using clinical criteria, including auscultation of bilateral breath sounds, symmetric chest expansion, and palpation of the endotracheal tube cuff in the suprasternal notch. The endotracheal tube position relative to the lower anterior incisors or alveolar ridge was recorded using the centimeter markings printed on the endotracheal tube. A chest radiograph was obtained after intubation to verify endotracheal tube position. Appropriate endotracheal tube position on chest radiograph was defined as between > 2 and < or = 6 cm above the carina.
MEASUREMENTS AND MAIN RESULTS: Of the 297 intubations, 26 were excluded from analysis because a chest radiograph was not obtained or the patient was not of normal stature. For the remaining 271 intubations, 42 (15.5%) endotracheal tubes were inappropriately placed, according to the radiographic assessment. The percentage of malpositioned endotracheal tubes was significantly higher in women than in men (61.9% vs. 38.1%, respectively; chi-square: p < .001). Thirty-three (78.6%) of 42 malpositioned endotracheal tubes were placed < 2 cm from the carina, with the highest occurrence (24/33) of proximal malposition occurring in women. Positioning of endotracheal tubes using the centimeter markings printed on the tube referenced to the lower incisors did not accurately identify malposition as documented by chest radiograph.
CONCLUSIONS: Emergent endotracheal intubations result in a significant occurrence of malpositioned endotracheal tubes that are undetected by clinical evaluation. Malpositioning is not detected by routine clinical assessment, but only by chest radiograph. Women are at greater risk than men for endotracheal tube malpositioning after emergent intubation; in women, the endotracheal tube is more likely to be positioned too close to the carina. A chest radiograph for confirmation of endotracheal tube position after emergent intubation should remain the standard of practice.

Entities:  

Mesh:

Year:  1994        PMID: 8026201     DOI: 10.1097/00003246-199407000-00013

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

Authors:  Kentaro Ouchi; Kazuna Sugiyama
Journal:  J Anesth       Date:  2015-11-30       Impact factor: 2.078

Review 2.  To breathe or not to breathe: a review of artificial airway placement and related complications.

Authors:  John Donatelli; Ayushi Gupta; Ramya Santhosh; Todd R Hazelton; Leelakrishna Nallamshetty; Alvaro Macias; Carlos A Rojas
Journal:  Emerg Radiol       Date:  2014-09-30

3.  Is a postintubation chest radiograph necessary in the emergency department?

Authors:  Daniel C McGillicuddy; Matthew R Babineau; Jonathan Fisher; Kevin Ban; Leon D Sanchez
Journal:  Int J Emerg Med       Date:  2009-11-19

4.  Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

Authors:  Christian Sitzwohl; Angelika Langheinrich; Andreas Schober; Peter Krafft; Daniel I Sessler; Harald Herkner; Christopher Gonano; Christian Weinstabl; Stephan C Kettner
Journal:  BMJ       Date:  2010-11-09

5.  Utility of postintubation chest radiographs in the intensive care unit.

Authors:  R Lotano; D Gerber; C Aseron; R Santarelli; M Pratter
Journal:  Crit Care       Date:  2000-01-24       Impact factor: 9.097

6.  Comparison of i-gel™ and laryngeal mask airway in anesthetized paralyzed patients.

Authors:  Seyed Mohammad Reza Hashemian; Navid Nouraei; Seyed Sadjad Razavi; Ebrahim Zaker; Alireza Jafari; Parivash Eftekhari; Golnar Radmand; Seyed Amir Mohajerani; Badiozzaman Radpay
Journal:  Int J Crit Illn Inj Sci       Date:  2014 Oct-Dec

7.  Intubation practice patterns in Tuscan emergency departments.

Authors:  Leon D Sanchez; Paolo Di Martino; Matthew Babineau; Michele Lanigra; Kevin M Ban
Journal:  Int J Emerg Med       Date:  2008-05-29

8.  Plain endotracheal tube insertion carries greater risk for malpositioning than does reinforced endotracheal tube insertion in females.

Authors:  Jin-Hee Han; Seung-Hoon Lee; Young-Jin Kang; Jong-Man Kang
Journal:  Korean J Anesthesiol       Date:  2013-12

9.  Radiographic hemithorax white-out following percutaneous nephrolithotomy.

Authors:  Alec Zhu; Adam B Weiner; Robert B Nadler
Journal:  Urol Case Rep       Date:  2017-12-11
  9 in total