Literature DB >> 8025895

Intraoperative ultrasonography of liver: detection of occult liver tumors and treatment by cryosurgery.

T S Ravikumar1, S Buenaventura, R R Salem, B D'Andrea.   

Abstract

A prospective study of 110 patients undergoing liver surgery was undertaken to evaluate the usefulness of intraoperative ultrasonography (IOUS) and cryosurgery in treating primary and metastatic liver tumors. The diagnoses were colorectal cancer (n = 72), hepatocellular carcinoma (n = 15), ovarian cancer (n = 8), cholangiocarcinoma (n = 4), and other tumors (n = 11). IOUS results were compared with preoperative CT scan angioportography. IOUS detected 37 lesions not seen on CT in 21 patients (19%) and 13 lesions not detected by bimanual palpation in 6 patients (5%). IOUS-assisted cryosurgery was carried out to ablate unresectable liver tumors in 21 patients (19%). At median follow-up of 14 months, 5/21 patients (24%) achieved complete response; 24 and 52% of patients recurred in the liver and systematically, respectively. Thus, IOUS is useful in detecting occult liver tumors and in providing assistance in tumor ablative therapies. Cryosurgery is useful in controlling some of the unresectable liver tumors, but the 76% recurrence rate implies the need for an effective regional and systemic chemo/immunotherapy.

Entities:  

Mesh:

Year:  1994        PMID: 8025895

Source DB:  PubMed          Journal:  Cancer Detect Prev        ISSN: 0361-090X


  5 in total

Review 1.  Cryosurgery in the treatment of liver metastasis from colorectal cancer.

Authors:  T S Ravikumar; R Sotomayor; R Goel
Journal:  J Gastrointest Surg       Date:  1997 Sep-Oct       Impact factor: 3.452

2.  Cryotherapy--a mature ablation technique.

Authors:  Sanjay M Kariappa; David L Morris
Journal:  HPB (Oxford)       Date:  2006       Impact factor: 3.647

3.  Hepatic cryosurgery for liver metastases. Long-term follow-up.

Authors:  N N Korpan
Journal:  Ann Surg       Date:  1997-02       Impact factor: 12.969

4.  Ablation of liver metastasis: is preoperative imaging sufficiently accurate?

Authors:  J R Wallace; K K Christians; F A Quiroz; W D Foley; H A Pitt; E J Quebbeman
Journal:  J Gastrointest Surg       Date:  2001 Jan-Feb       Impact factor: 3.452

Review 5.  The use of intra-operative ultrasound in gynecological surgery: a review.

Authors:  Karen Grewal; Benjamin Jones; Ariadne L'Heveder; Sita Jindal; Nicolas Galazis; Srdjan Saso; Joseph Yazbek
Journal:  Future Sci OA       Date:  2021-01-12
  5 in total