Literature DB >> 8021903

Number of measurements required for the analysis of diurnal blood pressure profile.

L Thijs1, J Staessen, R Fagard, P Zachariah, A Amery.   

Abstract

The aim of this study was to investigate how frequent blood pressure (BP) readings need to be obtained to reproduce the diurnal BP profile without loss or distortion of information. The subjects were 97 normotensives aged 23-84 years. Noninvasive ambulatory BP readings were programmed with an interval of 7.5 minutes during the day (from 8 am to 8 pm) and at 15 minutes intervals at night. Readings were stepwise omitted from the original recordings. For each step the diurnal BP profile was modelled with five different techniques. The concordance between original and reduced recordings was quantified using the repeatability coefficient, i.e. twice the standard deviation of the differences between these recordings (expressed as a percentage of the 5th to 95th percentile range of the parameter under investigation). The concordance between original and reduced recordings tended to be better for the level of pressure than for the parameters of the diurnal profile. If the sampling frequency was two readings per hour, concordance for SBP was < 10% for the BP level, 19% for the 24h standard deviation, 12% for the nocturnal fall in BP, 23% for the amplitude of the Fourier curve and 17% for the cusum derived circadian alteration magnitude. Concordance worsened to > 25% for most parameters of the diurnal BP curve when the interval between consecutive measurements exceeded 30 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8021903

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  6 in total

Review 1.  Implementing ABPM into Clinical Practice.

Authors:  Alan L Hinderliter; Raven A Voora; Anthony J Viera
Journal:  Curr Hypertens Rep       Date:  2018-02-05       Impact factor: 5.369

Review 2.  Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review.

Authors:  Daichi Shimbo; Marwah Abdalla; Louise Falzon; Raymond R Townsend; Paul Muntner
Journal:  Ann Intern Med       Date:  2015-10-13       Impact factor: 25.391

3.  How many measurements are needed to estimate blood pressure variability without loss of prognostic information?

Authors:  Luis J Mena; Gladys E Maestre; Tine W Hansen; Lutgarde Thijs; Yanping Liu; José Boggia; Yan Li; Masahiro Kikuya; Kristina Björklund-Bodegård; Takayoshi Ohkubo; Jørgen Jeppesen; Christian Torp-Pedersen; Eamon Dolan; Tatiana Kuznetsova; Katarzyna Stolarz-Skrzypek; Valérie Tikhonoff; Sofia Malyutina; Edoardo Casiglia; Yuri Nikitin; Lars Lind; Edgardo Sandoya; Kalina Kawecka-Jaszcz; Jan Filipovsky; Yutaka Lmai; Jiguang Wang; Eoin O'Brien; Jan A Staessen
Journal:  Am J Hypertens       Date:  2013-08-16       Impact factor: 2.689

4.  Conventional and Ambulatory Blood Pressure as Predictors of Diastolic Left Ventricular Function in a Flemish Population.

Authors:  Fang-Fei Wei; Wen-Yi Yang; Lutgarde Thijs; Zhen-Yu Zhang; Nicholas Cauwenberghs; Jan Van Keer; Qi-Fang Huang; Blerim Mujaj; Tatiana Kuznetsova; Karel Allegaert; Peter Verhamme; Jan A Staessen
Journal:  J Am Heart Assoc       Date:  2018-02-08       Impact factor: 5.501

Review 5.  Ambulatory blood pressure monitoring over 24 h: A Latin American Society of Hypertension position paper-accessibility, clinical use and cost effectiveness of ABPM in Latin America in year 2020.

Authors:  Ramiro A Sánchez; José Boggia; Ernesto Peñaherrera; Weimar Sebba Barroso; Eduardo Barbosa; Raúl Villar; Leonardo Cobos; Rafael Hernández Hernández; Jesús Lopez; José Andrés Octavio; José Z Parra Carrillo; Agustín J Ramírez; Gianfranco Parati
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-12       Impact factor: 3.738

6.  Mobile personal health system for ambulatory blood pressure monitoring.

Authors:  Luis J Mena; Vanessa G Felix; Rodolfo Ostos; Jesus A Gonzalez; Armando Cervantes; Armando Ochoa; Carlos Ruiz; Roberto Ramos; Gladys E Maestre
Journal:  Comput Math Methods Med       Date:  2013-05-09       Impact factor: 2.238

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.