Literature DB >> 8020649

Intraoperative and postoperative electrically evoked auditory brain stem responses in nucleus cochlear implant users: implications for the fitting process.

C J Brown1, P J Abbas, H Fryauf-Bertschy, D Kelsay, B J Gantz.   

Abstract

Electrically evoked auditory brain stem responses (EABR) were measured in 12 adults and 14 children with the Nucleus cochlear implant. Measures were made both intraoperatively and several months following surgery. EABR thresholds were consistently greater than clinically determined measures of behavioral threshold (T-level) but less than maximum comfort levels (C-level). When the data were pooled across subjects and different stimulating electrodes, EABR thresholds were strongly correlated with both T- and C-levels. In subjects where both intraoperative and postimplant EABR measures were obtained, intraoperative EABR thresholds were consistently higher than postimplant thresholds. The electrophysiologic data have been incorporated into a practical procedure for programming the implant in young children.

Entities:  

Mesh:

Year:  1994        PMID: 8020649     DOI: 10.1097/00003446-199404000-00006

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  7 in total

Review 1.  [Intra- and postoperative electrophysiological diagnostics].

Authors:  T Wesarg; S Arndt; A Aschendorff; R Laszig; R Beck; L Jung; S Zirn
Journal:  HNO       Date:  2017-04       Impact factor: 1.284

2.  Cochlear implants in children.

Authors:  S B Waltzman; W H Shapiro
Journal:  Trends Amplif       Date:  1999-12

3.  The relationship between electrically evoked compound action potential and speech perception: a study in cochlear implant users with short electrode array.

Authors:  Jae-Ryong Kim; Paul J Abbas; Carolyn J Brown; Christine P Etler; Sara O'Brien; Lee-Suk Kim
Journal:  Otol Neurotol       Date:  2010-09       Impact factor: 2.311

4.  Psychophysical and physiological measures of electrical-field interaction in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

5.  Radiological assessment of the Indian children with congenital sensorineural hearing loss.

Authors:  Sangeet Kumar Agarwal; Satinder Singh; Samarjit Singh Ghuman; Shalabh Sharma; Asish Kr Lahiri
Journal:  Int J Otolaryngol       Date:  2014-07-14

6.  Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants.

Authors:  Hongmei Hu; Mathias Dietz
Journal:  Trends Hear       Date:  2015-12-01       Impact factor: 3.293

7.  Longitudinal study of the ecap measured in children with cochlear implants.

Authors:  Liege Franzini Tanamati; Maria Cecília Bevilacqua; Orozimbo Alves Costa
Journal:  Braz J Otorhinolaryngol       Date:  2009 Jan-Feb