Literature DB >> 8017280

Effect of low-grade conductive heating on vascular compliance during in vitro balloon angioplasty.

J F Mitchel1, D B Fram, T A Aretz, L D Gillam, C Woronick, D D Waters, R G McKay.   

Abstract

Radiofrequency-powered, thermal balloon angioplasty is a new technique that enhances luminal dilatation with less dissection than conventional angioplasty. The purpose of this study was to assess the effect of radiofrequency heating of balloon fluid on the pressure-volume mechanics of in vitro balloon angioplasty and to determine the histologic basis for thermal-induced compliance changes. In vitro, radiofrequency-powered, thermal balloon angioplasty was performed on 46 paired iliac segments freshly harvested from 23 nonatherosclerotic pigs. Balloon inflations at 60 degrees C were compared to room temperature inflations in paired arterial segments. Intraballoon pressure and volume were recorded during each inflation as volume infusion increased pressure over a 0 to 10 atm range. Pressure-volume compliance curves were plotted for all dilatations. Six segments were stained to assess the histologic abnormalities associated with thermal compliance changes. Radiofrequency heating acutely shifted the pressure-volume curves rightward in 20 of 23 iliac segments compared to nonheated controls. This increase in compliance persisted after heating and exceeded the maximum compliance shift caused by multiple nonheated inflations in a subset of arterial segments. Histologically, heated segments showed increased thinning and compression of the arterial wall, increased medial cell necrosis and altered elastic tissue fibers compared to nonheated specimens. In conclusion, radiofrequency heating of intraballoon fluid to 60 degrees C acutely increases vascular compliance during in vitro balloon angioplasty of nonatherosclerotic iliac arteries. The increased compliance persists after heating and can be greater than the compliance shifts induced by multiple conventional dilatations. Arterial wall thinning and irreversible alteration of elastic tissue fibers probably account for thermal compliance changes.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8017280     DOI: 10.1016/0002-8703(94)90005-1

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  Effect of passive heat stress and exercise in the heat on arterial stiffness.

Authors:  Aaron R Caldwell; Forrest B Robinson; Matthew A Tucker; Cash H Arcement; Cory L Butts; Brendon P McDermott; Matthew S Ganio
Journal:  Eur J Appl Physiol       Date:  2017-06-13       Impact factor: 3.078

2.  Effect of passive heat stress on arterial stiffness.

Authors:  Matthew S Ganio; R Matthew Brothers; Shigeki Shibata; Jeffrey L Hastings; Craig G Crandall
Journal:  Exp Physiol       Date:  2011-06-17       Impact factor: 2.969

3.  The Deformation Rate of Smooth Muscle Cells in Vessel Walls After Short-Duration Heating Dilatation in a Porcine Model Ex Vivo and In Vivo.

Authors:  Mie Kunio; Tsunenori Arai
Journal:  Cardiovasc Eng Technol       Date:  2012-05-08       Impact factor: 2.495

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.