Literature DB >> 8014368

Differences between anatomical and physiological interpupillary distance.

E P Osuobeni1, M al-Fahdi.   

Abstract

BACKGROUND: The interpupillary distance (IPD) is usually measured between the centers of the pupils (anatomical IPD) or between the visual axes (physiological IPD). We have investigated the differences between the two methods of measuring IPD.
METHODS: A millimeter ruler was used to measure the distance between the nasal and lateral limbus of 400 male Arab subjects (anatomical IPD). An Essilor corneal reflex pupillometer was employed to also measure the inter visual axes distance (physiological IPD) of the same group of subjects.
RESULTS: The anatomical IPD is on the average 0.10mm and 0.30mm wider than the physiological IPD at distance and near respectively. The calculated near physiological IPD is significantly different from the measured near physiological IPD.
CONCLUSIONS: Although individual differences between anatomical and physiological IPDs could be clinically significant, generally, there is good agreement between the two. It is preferable to employ the monocular components of the physiological IPD in ophthalmic procedures.

Mesh:

Year:  1994        PMID: 8014368

Source DB:  PubMed          Journal:  J Am Optom Assoc        ISSN: 0003-0244


  4 in total

1.  Influence of age on measured anatomical and physiological interpupillary distance (far and near), and near heterophoria, in Arab males.

Authors:  Saud A Alanazi; Mana A Alanazi; Uchechukwu L Osuagwu
Journal:  Clin Ophthalmol       Date:  2013-04-16

2.  Nasopupillary asymmetry.

Authors:  Eduardo Arenas; Diana Muñoz; Evelyn Matheus; Diana Morales
Journal:  ScientificWorldJournal       Date:  2014-12-04

3.  Evaluation of interpupillary distance in the Turkish population.

Authors:  Yildiray Yildirim; Ibrahim Sahbaz; Taner Kar; Gamze Kagan; Mehmet Tolga Taner; Ilker Armagan; Begum Cakici
Journal:  Clin Ophthalmol       Date:  2015-08-03

4.  Agreement and inter-session repeatability of manual and automatic interpupillary distance measurements.

Authors:  Liat Gantz; Einat Shneor; Ravid Doron
Journal:  J Optom       Date:  2021-04-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.