[Pelvimetry using various magnetic resonance tomography techniques vs. digital image enhancement radiography: accuracy, time requirement and energy exposure].

K U Wentz1, K J Lehmann, A Wischnik, S Lange, R Suchalla, D H Grönemeyer, R M Seibel.   

Abstract

In 50 patients with suspected or proven cephalo-pelvine disproportion pelvimetry was performed with MR-tomography using a gradient-echo-sequence (FLASH 2D) before or after labour. Results were compared with measurements using digital radiography. In principle, both methods are exchangeable. The sagittal pelvic in- and outlet bispinous diameters are well reproducible. On the other hand, the transverse pelvic inlet and the distance between the ischiatic tubera are not so reliably reproduced. The accuracy of measurement does not depend on individual pelvic distances. Critical statistical analysis demonstrates, that in the worst case differences between the two methods might become unacceptable. Our results indicate two major reasons: 1. there are interobserver problems which cannot be neglected, and 2. the anatomical definition of referential landmarks for the measurements is unsafe. In 10 volunteers, a comparison was made between a T1-weighted spin-echo sequence (SE), a fast gradient echo sequence (FLASH-2D) and an ultrafast gradient echo technique (Turbo-FLASH). For the examination techniques presented here, the high-frequency exposure load or specific absorption rate (SAR loc and SAR total) is below the values permitted by the German Federal Health Bureau (Bundesgesundheitsamt). Whereas the exposure load in case of spin-echo takes (SE) is 22fold higher than with the gradient echo technique (GHE), the load values of ultra-fast GE (usGE) are only about 16% of the 2D-FLASH sequence or about 0.007% of SE. The difference in image quality does not affect the accuracy of measurement.

Entities:  

Mesh:

Year:  1994        PMID: 8013855     DOI: 10.1055/s-2007-1023583

Source DB:  PubMed          Journal:  Geburtshilfe Frauenheilkd        ISSN: 0016-5751            Impact factor:   2.915


  4 in total

1.  The anatomy of proximal femoral autografts for pelvic reconstruction: a cadaveric study.

Authors:  Shoufeng Wang; Jin Xiong; Chaoshuang Zhan; Aiguo Wang; Yixin Chen; Qing Jiang; Yong Qiu
Journal:  Surg Radiol Anat       Date:  2011-12-03       Impact factor: 1.246

2.  Potential of P40 plastination for morphometric hip measurements.

Authors:  B Genser-Strobl; M C Sora
Journal:  Surg Radiol Anat       Date:  2005-01-12       Impact factor: 1.246

3.  Three-dimensional pelvimetry by computed tomography.

Authors:  M Lenhard; T Johnson; S Weckbach; K Nikolaou; K Friese; U Hasbargen
Journal:  Radiol Med       Date:  2009-06-23       Impact factor: 3.469

4.  New MRI Criteria for Successful Vaginal Breech Delivery in Primiparae.

Authors:  Janine Hoffmann; Katrin Thomassen; Patrick Stumpp; Matthias Grothoff; Christoph Engel; Thomas Kahn; Holger Stepan
Journal:  PLoS One       Date:  2016-08-17       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.