Literature DB >> 8013198

The detection of foreign bodies in soft tissue--comparison of conventional and digital radiography.

C A Roobottom1, M J Weston.   

Abstract

The vast majority of glass and metallic foreign bodies can be detected with conventional radiography. The visibility of common woods and plastics is, however, unknown. To assess their radiographic visibility, various woods and plastics of equal size were inserted into fresh porcine tissue. The pork was then radiographed, under identical conditions, using conventional film-screen combination and a FUJI computed radiographic system utilizing its edge-enhancement facility. The visibility of the compounds was scored by four radiologists for both systems at various times post-insertion. Plastics were found to vary widely in visibility. Dried timbers were visible initially but became isodense with time due to absorption of fluid from surrounding tissues. Fresh woods were invisible from the outset. The computed radiographs improved the visibility of objects visible with conventional radiography but did not bring about visualization of those invisible to normal film-screen combinations. In conclusion the visibility of woods and plastics is variable. Some improvement in visibility can be brought about by the use of digitally edge-enhanced computed radiographs.

Mesh:

Substances:

Year:  1994        PMID: 8013198     DOI: 10.1016/s0009-9260(05)81799-4

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Delayed presentation of a penetrating neck injury: diagnostic and management difficulties with retained organic material.

Authors:  George Barrett; Catherine Williams; David Thomas
Journal:  JRSM Short Rep       Date:  2010-07-30

2.  Evaluation of Visibility of Foreign Bodies in the Maxillofacial Region: Comparison of Computed Tomography, Cone Beam Computed Tomography, Ultrasound and Magnetic Resonance Imaging.

Authors:  Solmaz Valizadeh; Hamidreza Pouraliakbar; Leila Kiani; Yaser Safi; Leila Alibakhshi
Journal:  Iran J Radiol       Date:  2016-08-10       Impact factor: 0.212

3.  Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro study.

Authors:  Mehrdad Abdinian; Maedeh Aminian; Samad Seyyedkhamesi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2018-02-26
  3 in total