Literature DB >> 8007766

Functional brain MR imaging based on bolus tracking with a fast T2*-sensitized gradient-echo method.

C T Moonen1, F A Barrios, J R Zigun, J Gillen, G Liu, G Sobering, R Sexton, J Woo, J Frank, D R Weinberger.   

Abstract

Dynamic physiological scanning, based on temporary changes in local field homogeneity during the passage of a contrast agent bolus, has been performed hitherto with echo-planar imaging (EPI) or conventional gradient-recalled techniques (FLASH). Here, it is shown that the T2* sensitivity of conventional FLASH techniques can be improved drastically on a conventional whole body instrument by delaying the gradient-echo until the subsequent TR-period without increasing total imaging time. Examples are given for a full k-space matrix (128 x 256) obtained within 2 s with a TE of 25 ms, resulting in images free of artifacts. The method is applied to bolus tracking through the brain of healthy volunteers during visual stimulation and in the dark. An average increase of regional cerebral blood volume (rCBV) in the visual cortex of 10.9% (n = 9, p = .001) was found.

Mesh:

Substances:

Year:  1994        PMID: 8007766     DOI: 10.1016/0730-725x(94)92530-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

Review 1.  The PRESTO technique for fMRI.

Authors:  P van Gelderen; J H Duyn; N F Ramsey; G Liu; C T W Moonen
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

2.  Effects of three different doses of a bolus injection of gadodiamide: assessment of regional cerebral blood volume maps in a blinded reader study.

Authors:  R Bruening; C Berchtenbreiter; N Holzknecht; M Essig; R H Wu; A Simmons; A Heuck; A Maschek; M Meusel; S C Williams; T Cox; M V Knopp; M Reiser
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

Review 3.  Functional Imaging of Autonomic Regulation: Methods and Key Findings.

Authors:  Paul M Macey; Jennifer A Ogren; Rajesh Kumar; Ronald M Harper
Journal:  Front Neurosci       Date:  2016-01-26       Impact factor: 4.677

4.  Increased fMRI Sensitivity at Equal Data Burden Using Averaged Shifted Echo Acquisition.

Authors:  Suzanne T Witt; Marcel Warntjes; Maria Engström
Journal:  Front Neurosci       Date:  2016-11-23       Impact factor: 4.677

5.  SNR-Enhanced, Rapid Electrical Conductivity Mapping Using Echo-Shifted MRI.

Authors:  Hyunyeol Lee; Jaeseok Park
Journal:  Tomography       Date:  2022-02-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.