| Literature DB >> 8006155 |
M F Abel1, D R Wenger, S J Mubarak, D H Sutherland.
Abstract
Cerebral palsy patients (31 hips) were evaluated using radiographic and three-dimensional (3-D) images to quantify hip anatomy. The 3-D images overcome distortions caused by joint contractures. Changes were more pronounced in the non-ambulators and characterized by shallow sockets with increased neck-shaft angles. These hips tended to subluxate in a posterior-superior direction and most had defects in the femoral heads. Ambulators had increased femoral anterversion but other hip parameters tended to improve with age. The 3-D measures of roof steepness and socket depth were found to correlate strongly with radiographic parameters of subluxation.Entities:
Mesh:
Year: 1994 PMID: 8006155 DOI: 10.1097/01241398-199405000-00002
Source DB: PubMed Journal: J Pediatr Orthop ISSN: 0271-6798 Impact factor: 2.324