Literature DB >> 8001033

Developments in non-radioactive microsphere techniques for blood flow measurement.

F W Prinzen1, R W Glenny.   

Abstract

Considerable progress is being made in the development of non-radioactive microsphere methods. Validation studies of the three commercially available non-radioactive microspheres are promising. In most experimental conditions the use of non-radioactive microspheres saves money. Avoiding the use of radioactivity facilitates the use of microspheres in chronic animal experiments and when blood flow and chemical measurements are performed in the same sample. Moreover, using histological techniques, distributions of coloured or fluorescent microspheres in subunits of organs could be quantified, opening new scientific possibilities. Currently, the fluorescent microsphere technique seems to be the most promising non-radioactive microsphere method. Due to the high sensitivity and good spectral separation, the number of microspheres injected can be as small as that used, for radioactive microspheres, at least six labels can be used, and the relatively large volume in which fluorescence is measured (approximately 1-3 ml) enables the use of time saving microsphere isolation techniques. Development of these methods and further automation of the quantification process (using either automised spectrometry or FACS analysis) will considerably increase interest in the non-radioactive microsphere techniques. To accelerate these developments, investigators are encouraged to share their experiences.

Mesh:

Year:  1994        PMID: 8001033     DOI: 10.1093/cvr/28.10.1467

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  15 in total

Review 1.  Blood flow distributions by microsphere deposition methods.

Authors:  F W Prinzen; J B Bassingthwaighte
Journal:  Cardiovasc Res       Date:  2000-01-01       Impact factor: 10.787

2.  Temperature and perfusion responses of muscle and lung tissue during chronic heating in vivo.

Authors:  G M Saidel; C R Davies; E H Liu; H Harasaki
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

Review 3.  Skeletal Blood Flow in Bone Repair and Maintenance.

Authors:  Ryan E Tomlinson; Matthew J Silva
Journal:  Bone Res       Date:  2013-12-31       Impact factor: 13.567

4.  Morphological and functional evidence, and clinical importance, of vascular anastomoses in the latissimus dorsi muscle of the sheep.

Authors:  S Salmons; A T Tang; J C Jarvis; H Degens; M Hastings; T L Hooper
Journal:  J Anat       Date:  1998-07       Impact factor: 2.610

Review 5.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

6.  Comparison of neutron activated and radiolabeled microsphere methods for measurement of transmural myocardial blood flow in dogs.

Authors:  John G Kingma; Denys Simard; Jacques R Rouleau
Journal:  J Thromb Thrombolysis       Date:  2005-06       Impact factor: 2.300

7.  Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches.

Authors:  Susan R Hopkins
Journal:  Compr Physiol       Date:  2020-07-08       Impact factor: 9.090

8.  Regional intestinal blood flow and nitric oxide synthase inhibition during sepsis in the rat.

Authors:  K Klemm; F G Moody
Journal:  Ann Surg       Date:  1998-01       Impact factor: 12.969

Review 9.  Lung perfusion measured using magnetic resonance imaging: New tools for physiological insights into the pulmonary circulation.

Authors:  Susan R Hopkins; G Kim Prisk
Journal:  J Magn Reson Imaging       Date:  2010-12       Impact factor: 4.813

10.  Near infrared spectroscopy for measuring changes in bone hemoglobin content after exercise in individuals with spinal cord injury.

Authors:  Adina E Draghici; Diane Potart; Joseph L Hollmann; Vivian Pera; Qianqian Fang; Charles A DiMarzio; J Andrew Taylor; Mark J Niedre; Sandra J Shefelbine
Journal:  J Orthop Res       Date:  2017-06-28       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.