Comparative analysis of results of guaiac and immunochemical tests for faecal occult blood in colorectal cancer screening in two oncological institutions.

G Castiglione1, P Sala, S Ciatto, G Grazzini, A Mazzotta, C Rossetti, P Spinelli, L Bertario.   

Abstract

The performances of three faecal occult blood tests, rehydrated Hemoccult (HOR), Hemoccult sensa (HOS) and Hemeselect (HSEL) on 3 days were compared in 1,725 subjects consecutively recruited in two oncological institutions in Milan and Florence. Significant differences between the results were evident as far as HOR positivity rates (7.5% vs 4.0%, respectively) and specificity (94.3% vs 97.5%, respectively) are concerned. Overall positivity rates of HOR, HOS and HSEL were 5.9%, 5.4% and 12%, respectively; significant differences were evident between HSEL and each of the two guaiac tests. Cancer was detected in eight subjects, adenoma/s in 47. Specificity estimates were 95.8%, 90.2% and 90.5% for HOR, HOS and HSEL, respectively; significant differences were evident between HSEL and the other two tests. No significant difference between tests was evident for sensitivity or positive predictive values for cancer or adenomas. In the CSPO (Florence) population (1,223 subjects; five with cancer, 16 with adenoma/s) the performances of 1-day HSEL testing were determined on the basis of the first faecal sample only and compared with 3-day HOR, HOS and HSEL testing. The positivity rates of 1-day HSEL, 3-day HOR, HOS and HSEL testing were 7.0%, 5.0%, 5.5% and 12.9%, respectively. Only 3-day HSEL positivity rate was significantly higher than 1-day HSEL. One-day HSEL specificity (94.9%) was significantly higher than 3-day HSEL (90.0%), whereas no significant difference was seen between 1-day HSEL, HOR (96.5%), and HOS (96.1%) specificity. No significant difference between tests is evident in the CSPO population as far as positive predictive values and sensitivity for cancer and adenomas are concerned.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8000308     DOI: 10.1097/00008469-199409000-00003

Source DB:  PubMed          Journal:  Eur J Cancer Prev        ISSN: 0959-8278            Impact factor:   2.497


  3 in total

1.  Diagnostic accuracy of immunochemical versus guaiac faecal occult blood tests for colorectal cancer screening.

Authors:  Adolfo Parra-Blanco; Antonio Z Gimeno-García; Enrique Quintero; David Nicolás; Santiago G Moreno; Alejandro Jiménez; Manuel Hernández-Guerra; Marta Carrillo-Palau; Yoshinobu Eishi; Julio López-Bastida
Journal:  J Gastroenterol       Date:  2010-02-17       Impact factor: 7.527

2.  Performance characteristics and comparison of two immunochemical and two guaiac fecal occult blood screening tests for colorectal neoplasia.

Authors:  P Rozen; J Knaani; Z Samuel
Journal:  Dig Dis Sci       Date:  1997-10       Impact factor: 3.199

3.  Immunochemical vs guaiac faecal occult blood tests in a population-based screening programme for colorectal cancer.

Authors:  G Castiglione; M Zappa; G Grazzini; A Mazzotta; M Biagini; P Salvadori; S Ciatto
Journal:  Br J Cancer       Date:  1996-07       Impact factor: 7.640