Literature DB >> 7998543

Percutaneous biopsy of the liver and kidney by using coaxial technique: adequacy of the specimen obtained with three different needles in vitro.

K D Hopper1, R T Grenko, T R TenHave, J Hartzel, K W Sturtz, C A Savage.   

Abstract

OBJECTIVE: The coaxial biopsy technique was evaluated with respect to the quality of specimens obtained from the liver and kidneys in vitro on sequential biopsies at the same site with each of three different biopsy needles.
MATERIALS AND METHODS: For each of three different biopsy needles (aspiration 18-gauge Chiba, 18-gauge Sure-Cut, and 18-gauge Biopty), 30 sites (15 liver, 15 kidney) were selected for in vitro coaxial biopsy. At each site, an introducer was placed, through which three sequential biopsies were done. Blinded histopathologic analysis was used to grade the quality of specimens on a scale from 0 (no tissue) to 3 (best) for three criteria: adequacy of tissue for diagnosis, tissue fragmentation, and crush artifact. The overall score was the sum of the scores for the three individual criteria and ranged from 0 (no tissue) to 9 (best).
RESULTS: Using an 18-gauge Chiba needle and coaxial technique, we found no significant reduction in specimen quality when we did multiple aspiration biopsies at the same site. However, no tissue was obtained (zero biopsy) from a large number of aspiration biopsies done with the Chiba needle, ranging from 24 of 30 for the first biopsy to 17 of 30 for the third biopsy. Specimen quality was reduced somewhat between the first and third biopsies when the 18-gauge Sure-Cut and Biopty needles were used. With the Sure-Cut needle, this reduction in quality was significant (p = .009) and was primarily related to increased tissue fragmentation and crushing. The reduction in quality with multiple biopsy attempts was less severe with the Biopty needle/gun. Although the mean score decreased from 6.6 for the first biopsy to 5.5 for the third biopsy, this reduction was not significant (p = .06). In addition, the Biopty gun, unlike the other two needles, had few zero biopsies.
CONCLUSION: The use of a coaxial technique with an 18-gauge Biopty needle enables collection of a large amount of high-quality tissue for histopathologic analysis with a minimum number of failed biopsies as compared with the 18-gauge Chiba needle and the 18-gauge Sure-Cut needle.

Entities:  

Mesh:

Year:  1995        PMID: 7998543     DOI: 10.2214/ajr.164.1.7998543

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Assessment of bone biopsy needles for sample size, specimen quality and ease of use.

Authors:  C C Roberts; W B Morrison; K O Leslie; J A Carrino; J L Lozevski; P T Liu
Journal:  Skeletal Radiol       Date:  2005-03-11       Impact factor: 2.199

2.  Effectiveness and safety of ultrasound-guided percutaneous liver biopsy in children.

Authors:  Hugo Matos; Maria José Noruegas; Isabel Gonçalves; Conceição Sanches
Journal:  Pediatr Radiol       Date:  2012-08-24

3.  Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle.

Authors:  S Diederich; B Padge; U Vossas; R Hake; S Eidt
Journal:  Cancer Imaging       Date:  2006-06-08       Impact factor: 3.909

4.  Injecting hemostatic matrix in the path of biopsies: efficacy, potential complications, and the management of such complications.

Authors:  Antonio Rahal Junior; Priscila Mina Falsarella; Vinicius Tadeu Rodrigues Ferreira; Guilherme Cayres Mariotti; Marcos Roberto Gomes de Queiroz; Rodrigo Gobbo Garcia
Journal:  Radiol Bras       Date:  2018 Mar-Apr

5.  Percutaneous biopsy of abdominal lesions: what is currently the best diagnostic strategy?

Authors:  Thiago Franchi Nunes
Journal:  Radiol Bras       Date:  2018 May-Jun