Literature DB >> 7998539

CT percutaneous biopsy guns: comparison of end-cut and side-notch devices in cadaveric specimens.

K D Hopper1, C S Abendroth, K W Sturtz, Y L Matthews, J S Hartzel, P S Potok.   

Abstract

OBJECTIVE: The purpose of this study was to compare the efficacies of four different types of end-cut biopsy guns with the side-notch Tru-cut biopsy gun.
MATERIALS AND METHODS: A total of 25 liver, 15 kidney, 10 pancreas, and 15 breast biopsies were performed in the tissue from five autopsies with each of 12 different biopsy devices/biopsy depths. The tissue obtained was evaluated by an experienced cytopathologist who, not knowing which gun was used to obtain each specimen, used a predetermined grading scheme.
RESULTS: When tissue was obtained, the end-cut biopsy guns performed equivalently to the side-notch biopsy gun in all four tissues. However, the end-cut guns had a significant number of "zero" biopsies (biopsy attempts during which no tissue was obtained). The proportion of zero biopsies with the end-cut guns ranged from up to 28% in the liver to 60% and 73% in the breast and kidney, respectively.
CONCLUSION: The end-cut biopsy guns are easy to use and potentially can obtain high-quality specimens. However, the rate of zero biopsies during which no tissue is obtained is a serious deficiency. As a result, the use of the end-cut biopsy gun should be encouraged only for use with an introducer, with which multiple biopsy specimens can easily be obtained without additional needle punctures.

Entities:  

Mesh:

Year:  1995        PMID: 7998539     DOI: 10.2214/ajr.164.1.7998539

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  Value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas using automated biopsy gun.

Authors:  Li Li; Qiu-Liang Wu; Li-Zhi Liu; Yun-Xian Mo; Chuan-Miao Xie; Lie Zheng; Lin Chen; Pei-Hong Wu
Journal:  World J Gastroenterol       Date:  2005-08-21       Impact factor: 5.742

2.  Beyond isolated cells: microfluidic transport of large tissue for pancreatic cancer diagnosis.

Authors:  Ronnie Das; Rachel G Murphy; Eric J Seibel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-05

3.  Needle types used in abdominal cross-sectional interventional radiology: a survey of the Society of Abdominal Radiology emerging technology commission.

Authors:  Benjamin Wildman-Tobriner; Lisa M Ho; Andrew W Bowman
Journal:  Abdom Radiol (NY)       Date:  2021-06-14

4.  The diagnostic quality of needle brain biopsy specimens obtained with different sampling methods - Experimental study.

Authors:  Piotr Trojanowski; Bożena Jarosz; Dariusz Szczepanek
Journal:  Sci Rep       Date:  2019-05-30       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.