Literature DB >> 7998523

Evaluation of the renal arteries in kidney donors: value of three-dimensional phase-contrast MR angiography with maximum-intensity-projection or surface rendering.

S P Meyers1, S L Talagala, S Totterman, M V Azodo, E Kwok, L Shapiro, R Shapiro, R C Pabico, G R Applegate.   

Abstract

OBJECTIVE: Donors routinely undergo preoperative conventional arteriography to evaluate the renal arteries before nephrectomy. The purpose of this study was to assess the capability of three-dimensional phase-contrast MR angiograms postprocessed with maximum-intensity-projection and surface-rendering techniques to show the renal arteries of potential donors.
MATERIALS AND METHODS: Postprocessed three-dimensional phase-contrast MR angiograms of 17 patients were retrospectively reviewed by two experienced radiologists for the number and length of renal arteries visualized. Conventional arteriograms were used as the reference standard. Coronal maximum-intensity-projection and surface-rendered MR angiograms were also compared with each other with regard to the delineation of renal arteries from overlapping vessels.
RESULTS: MR angiograms showed all 34 single or dominant renal arteries but only eight of 10 accessory arteries seen on conventional arteriograms. One of the nonvisualized accessory arteries was located within the imaged volume, and the other one arose from the distal aorta beyond the imaged regions. Five of six arterial branches arising from the proximal 30-mm portions of the renal arteries were seen on MR angiograms. Postprocessing with either maximum-intensity projection or surface-rendering showed the same number of renal arteries, although surface rendering separated overlapping veins from the renal arteries better than the maximum-intensity-projection technique.
CONCLUSION: These results suggest that three-dimensional MR angiography is a reliable method of imaging single or dominant renal arteries, but not for showing all accessory renal arteries and small arterial branches. Surface rendering may provide specific advantages over maximum-intensity-projection in delineating renal arteries from overlapping vessels.

Entities:  

Mesh:

Year:  1995        PMID: 7998523     DOI: 10.2214/ajr.164.1.7998523

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  Spiral computed tomographic angiography of the renal arteries: a prospective comparison with intravenous and intraarterial digital subtraction angiography.

Authors:  M T Farrés; J Lammer; W Schima; B Wagner; R Wildling; F Winkelbauer; S Thurnher
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Mar-Apr       Impact factor: 2.740

2.  Frequencies of accessory renal arteries in 129 Iranian patients.

Authors:  Hadi Maleki; Reza Shahriar; Reza Kazemi; Farinaz Khodadadi
Journal:  Am J Clin Exp Urol       Date:  2020-02-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.