Literature DB >> 7996323

The reliability of detecting screw penetration of the acetabulum by intraoperative auscultation.

J O Anglen1, T DiPasquale.   

Abstract

Open reduction and internal fixation of the acetabulum frequently requires placement of screws in a blind fashion that risks penetrating the joint surface. While in the operative suite, direct visualization of the joint surface may not be possible, and fluoroscopy can be difficult to interpret. Auscultation of the hip with motion in a quiet room has been suggested as a useful adjunct to detecting screw penetration. Carrying that concept further, we auscultate the hip using a sterile esophageal stethoscope at the operating table and have found this to be a highly reliable method of detecting intraarticular screw placement. To test the reliability and reproducibility of this technique, an experiment was performed using inexperienced volunteers. In part I, two adult mongrel dogs were prepared. A screw was placed violating the hip joint in one dog, and in the other dog a screw was placed near but not penetrating the joint. Screw placement was verified under direct vision. Seventy-seven volunteers who did not know which hip was penetrated then auscultated both hips in random order and recorded their impressions after each hip was heard. After hearing both hips, 74 of 77 were able to identify the screw in the hip joint correctly; 69 were able to recognize the extraarticular screw correctly. In part II, both hips of a human cadaver were exposed and dislocated. In one hip, a screw was placed that tangentially violated the joint, and in the same area of the contralateral hip a screw was placed that did not penetrate the joint surface.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7996323     DOI: 10.1097/00005131-199410000-00006

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  7 in total

1.  Assessment of Intra-articular Screw Penetration During Radial Head and Olecranon Locking Plate Fixation: A Cadaveric Study.

Authors:  Ismar Dizdarevic; Claire M Eden; Matthew Bengard; O Alton Barron; Louis W Catalano; Steven Z Glickel
Journal:  Hand (N Y)       Date:  2016-01-14

2.  A safe technique of anterior column lag screw fixation in acetabular fractures.

Authors:  Ramesh Kumar Sen; Sujit Kumar Tripathy; Sameer Aggarwal; Tarun Goyal; Dharm S Meena; Santosh Mahapatra
Journal:  Int Orthop       Date:  2012-09-23       Impact factor: 3.075

3.  [The postoperative control CT after a fracture of the acetabulum. A useful quality control measure or an unnecessary exposure to radiation?].

Authors:  R Eberl; E J Müller; A Kaminski; G Muhr
Journal:  Unfallchirurg       Date:  2003-09       Impact factor: 1.000

4.  Comparative study of anatomical locking plate and reconstruction plate in treating acetabular fractures.

Authors:  Zhijiang Li; Jiantao Li; Zhirui Li; Shaobo Nie; Hao Zhang; Ming Li; Jianheng Liu; Zhongyang Liu; Gaoxiang Xu; Licheng Zhang; Peifu Tang
Journal:  Int Orthop       Date:  2021-02-14       Impact factor: 3.075

5.  The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans.

Authors:  Chun Bi; Jiandong Wang; Xiaoxi Ji; Zhijian Ma; Fang Wang; Xiangsen Zeng; Dongmei Wang; Qiugen Wang
Journal:  BMC Musculoskelet Disord       Date:  2017-02-20       Impact factor: 2.362

6.  Digital anatomical study and clinical application of screw placement for quadrilateral plate fractures in the danger zone.

Authors:  Bei Zhao; Zhongye Sun; Wei Zhang; Zhongbao Xu; Xiaofei Yang; Weidong Mu
Journal:  BMC Musculoskelet Disord       Date:  2020-04-11       Impact factor: 2.362

7.  Biaxial reduction technique for the medially displaced quadrilateral surface in acetabular fracture through the modified iliofemoral approach: An observational study.

Authors:  Byung Hoon Lee
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817