Literature DB >> 7996091

Comparison of apical leakage in root canals obturated with various gutta percha techniques using a dye vacuum tracing method.

D M Dalat1, L S Spångberg.   

Abstract

In this study, residual apical microlumina remaining after obturation with five different gutta-percha obturation methods were traced with an efficient vacuum method. Seventy-nine human maxillary anterior teeth were instrumented and divided into five groups. The groups were obturated with single-cone techniques, lateral condensation, vertical condensation, Thermafil, and Ultrafil techniques. All specimens were immersed in a vacuum flask containing 2% methylene blue dye solution. The air was evacuated with a vacuum pump to an absolute pressure of 75 torr for 30 min. The roots were sectioned longitudinally and the linear extent of dye penetration was measured. Group mean linear dye penetration values were: single-cone technique, 1.55 +/- 0.95 mm; lateral condensation, 2.25 +/- 1.46 mm; vertical condensation, 2.61 +/- 2.61 mm; Thermafil 1.41 +/- 1.16 mm; and Ultrafil 3.51 +/- 4.70 mm. There were no statistically significant differences between the gutta-percha obturation methods. The clinical implications of these findings are discussed.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7996091     DOI: 10.1016/s0099-2399(06)80092-0

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  A simplified post preparation technique after Thermafil obturation: evaluation of apical microleakage and presence of voids using methylene blue dye penetration.

Authors:  Luca Pusinanti; Riccardo Rubini; Agnese Pellati; Nicoletta Zerman
Journal:  Ann Stomatol (Roma)       Date:  2013-06-25

2.  An in vitro assessment of apical microleakage in root canals obturated with gutta-flow, resilon, thermafil and lateral condensation: A stereomicroscopic study.

Authors:  Sandhya Kapoor Punia; Prasannalatha Nadig; Vikas Punia
Journal:  J Conserv Dent       Date:  2011-04

3.  Comparison of root canal sealer distribution in obturated root canal: An in-vitro study.

Authors:  Gaurav Setya; Ajay Nagpal; Sunil Kumar; Navin Anand Ingle
Journal:  J Int Soc Prev Community Dent       Date:  2014-09

4.  An In Vitro Comparative Evaluation of Distribution of Three Different Sealers by Single-Cone Obturation Technique.

Authors:  Chandrika Ramanathan Palanivelu; Vaiyapuri Ravi; Arthanarieswaran Andamuthu Sivakumar; Jambai Sampathkumar Sivakumar; Anjaneya Shiva Prasad; Kaneesh Karthik Arthanari
Journal:  J Pharm Bioallied Sci       Date:  2019-05

5.  Comparative Evaluation of Fracture Resistance of Endodontically Treated Bicuspids Instrumented With Hand Files, TruNatomy, ProTaper Next, ProTaper Gold, and WaveOne - An In vitro Study.

Authors:  Sulfia Nassar; Harish Kumar Shetty; Prathap M S Nair; Sree Gowri; K Jayaprakash
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

6.  Copper ion as a new leakage tracer.

Authors:  J Modaresi; M Baharizade; A Shareghi; M Ahmadi; A Daneshkazemi
Journal:  J Dent (Shiraz)       Date:  2013-12

7.  Dentinal defects before and after rotary root canal instrumentation with three different obturation techniques and two obturating materials.

Authors:  Ponnuswamy Kumaran; Elangovan Sivapriya; Jamuna Indhramohan; Velayutham Gopikrishna; K Subramani Savadamoorthi; Angambakkam Rajasekharan Pradeepkumar
Journal:  J Conserv Dent       Date:  2013-11
  7 in total