Terbutaline via pressurised metered dose inhaled (P-MDI) and Turbuhaler in highly reactive asthmatic patients.

L Jackson1, E Ståhl, S T Holgate.   

Abstract

There is some concern over the environmental consequences of chlorofluorocarbons (CFCs) used in pressurized metered-dose inhalers (p-MDIs). Turbuhaler was designed to deliver a drug as a dry powder without administering additives directly to the airways. The aim of this study was to evaluate the comparative irritant and bronchodilating effects of the same dose of terbutaline delivered by a p-MDI and via Turbuhaler. Ten symptomatic, asthmatic patients, with highly reactive airways (provocative concentration of methacholine producing a 20% fall in forced expiratory volume in one second (PC20) < 0.2 mg.ml-1), inhaled, on separate days, 0.25 mg terbutaline via p-MDI or Turbuhaler. Changes in airway calibre were followed as specific airways conductance (sGaw). On a third day, patients inhaled from a placebo p-MDI containing all constituents except terbutaline. The study was conducted in a single-blind fashion and in random order. There were no significant differences in baseline sGaw on any of the study days. Inhalation of terbutaline from the p-MDI produced a transient percentage fall in sGaw at 1 min, reaching a mean maximum +/- SD of 17 +/- 8% at 10 s and then returning to baseline value after 20 s, followed by a progressive increase in sGaw to a maximum of 39 +/- 45% above baseline at 45 min. In contrast, inhalation of terbutaline via Turbuhaler caused no significant bronchoconstriction (fall in sGaw, 3 +/- 16%) at 10 s and achieved a greater increase in sGaw, reaching 63 +/- 51% at 45 min, although just failing to reach statistical significance compared to terbutaline p-MDI inhalation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7995387     DOI: 10.1183/09031936.94.07091598

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  3 in total

1.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.

Authors:  F S Ram; J Wright; D Brocklebank; J E White
Journal:  BMJ       Date:  2001-10-20

2.  Comparison of terbutaline and placebo from a pressurised metered dose inhaler and a dry powder inhaler in a subgroup of patients with asthma.

Authors:  O Selroos; A B Löfroos; A Pietinalho; H Riska
Journal:  Thorax       Date:  1994-12       Impact factor: 9.139

Review 3.  Review of therapeutically equivalent alternatives to short acting beta(2) adrenoceptor agonists delivered via chlorofluorocarbon-containing inhalers.

Authors:  D A Hughes; A Woodcock; T Walley
Journal:  Thorax       Date:  1999-12       Impact factor: 9.139

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.