Literature DB >> 7994203

Comparison of extra-cellular fluid volume measurement in children by 99Tcm-DPTA clearance and multi-frequency impedance techniques.

S W Smye1, H M Norwood, T Buur, M Bradbury, J T Brocklebank.   

Abstract

Comparisons of extra-cellular fluid (ECF) volume estimates made by isotope dilution and electrical impedance techniques have been made in a group of 16 children. For each patient an estimate of ECF volume (Vt) was obtained from measurements of the blood clearance of 99Tcm-diethylene triamine penta-acetate (DPTA) which was compared with two estimates (Vi1 and Vi2) of ECF volume obtained from measurements of the whole-body electrical impedance at 50 frequencies in the range 1 kHz to 1.348 MHz and a third estimate Vh based on patient height, L, alone. The observed frequency response of the impedance measurements was fitted to a three-element equivalent-circuit model of whole-body impedance and gave a value of the ECF resistance R. Vi1 was obtained from Vi1 = a (L2/R) + b. Vi2 was given by c(W1/2L2/R)2/3 where W is the patient weight, and Vh was given by dL2 + e. The constants a, b, c, d, e were determined by comparison with Vt and were equal to 0.335 l omega m-2 (standard error = 0.01 1 omega m-2), 0.42 l (0.25 l), 0.33 l (omega 2kg-1m-4)1/2 0.007 l (omega 2kg-1m-4)1/3, 4.92 l m-2 (2.8 x 10(-5) lm-2), 0.13 l (0.41 l), respectively. Vi1, Vi2, Vh were linearly correlated with Vt (r2 = 0.98, 0.99, 0.95, respectively, p < 0.001), and upper and lower levels of agreement were given by +/- 0.95 l (Vt and Vi1), 1.44 l and -1.12 l (Vt and Vi2), +/- 1.5 l (Vt and Vh), respectively. Thus inclusion of the impedance data accounted for greater volume variation, but differences between the techniques were not significant (paired t-test and Mann-Whitney analysis) suggesting that more accurate and detailed measurements are required.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7994203     DOI: 10.1088/0967-3334/15/3/003

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Total body water measurement in renal insufficiency.

Authors:  M G Bradbury; J T Brocklebank; S W Smye; P S Davies
Journal:  Pediatr Nephrol       Date:  1996-04       Impact factor: 3.714

2.  Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis.

Authors:  H Scharfetter; G H Wirnsberger; H Holzer; H Hutten
Journal:  Med Biol Eng Comput       Date:  1997-03       Impact factor: 2.602

3.  Assessment of the sensitivity of bioimpedance to volume changes in body water.

Authors:  M G Bradbury; S W Smye; J T Brocklebank
Journal:  Pediatr Nephrol       Date:  1995-06       Impact factor: 3.714

Review 4.  Fluid balance concepts in medicine: Principles and practice.

Authors:  Maria-Eleni Roumelioti; Robert H Glew; Zeid J Khitan; Helbert Rondon-Berrios; Christos P Argyropoulos; Deepak Malhotra; Dominic S Raj; Emmanuel I Agaba; Mark Rohrscheib; Glen H Murata; Joseph I Shapiro; Antonios H Tzamaloukas
Journal:  World J Nephrol       Date:  2018-01-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.