Literature DB >> 7992112

Bone marrow blood supply in gadolinium-enhanced magnetic resonance imaging.

A Saifuddin1, K Bann, J P Ridgway, W P Butt.   

Abstract

A retrospective study was performed to determine whether bone blood supply can be assessed on gadolinium-enhanced magnetic resonance imaging. Lumbar spine magnetic resonance imaging (MRI) examinations of 49 patients attending for post-laminectomy examination were reviewed (30 male, 19 female, mean age 46.4 years, age range 23-84 years). Each study included sagittal T1-weighted spin echo sequences before and after gadolinium administration. Regions of interest were drawn within the L3 vertebral body from a parasagittal slice from each sequence. Signal intensity (SI) values were ascertained and the percentage increase in SI was calculated. For each patient, changes in receiver gain for pre- and post-gadolinium images were corrected by an image scaling factor. In all cases, a measurable increase in SI was found (mean 15.3%, range 4.4-55.7) due to bone vascularity. The results give no indication of the quantity or timing of blood supply but provide a basis for further work.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7992112     DOI: 10.1007/BF00204608

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  6 in total

1.  Dynamic MR imaging of the abdomen with gadopentetate dimeglumine: normal enhancement patterns of the liver, spleen, stomach, and pancreas.

Authors:  M M Hamed; B Hamm; M E Ibrahim; M Taupitz; A E Mahfouz
Journal:  AJR Am J Roentgenol       Date:  1992-02       Impact factor: 3.959

2.  Normal abdominal enhancement patterns with dynamic gadolinium-enhanced MR imaging.

Authors:  S A Mirowitz; E Gutierrez; J K Lee; J J Brown; J P Heiken
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

3.  Acute fracture of the femoral neck: assessment of femoral head perfusion with gadopentetate dimeglumine-enhanced MR imaging.

Authors:  P Lang; M Mauz; W Schörner; G Schwetlick; H Henkes; Y Berthezene; S Grampp; H E Jergesen; A Mühler; R Felix
Journal:  AJR Am J Roentgenol       Date:  1993-02       Impact factor: 3.959

4.  Bone marrow perfusion evaluated with gadolinium-enhanced dynamic fast MR imaging in a dog model.

Authors:  M Cova; Y S Kang; H Tsukamoto; L C Jones; E McVeigh; B L Neff; C J Herold; W W Scott; D S Hungerford; E A Zerhouni
Journal:  Radiology       Date:  1991-05       Impact factor: 11.105

5.  Evaluation of marrow perfusion in the femoral head by dynamic magnetic resonance imaging. Effect of venous occlusion in a dog model.

Authors:  H Tsukamoto; Y S Kang; L C Jones; M Cova; C J Herold; E McVeigh; D S Hungerford; E A Zerhouni
Journal:  Invest Radiol       Date:  1992-04       Impact factor: 6.016

Review 6.  Gadopentetate dimeglumine-enhanced MR imaging of the musculoskeletal system.

Authors:  J Beltran; V Chandnani; R A McGhee; S Kursunoglu-Brahme
Journal:  AJR Am J Roentgenol       Date:  1991-03       Impact factor: 3.959

  6 in total
  1 in total

1.  MRI of bone metastases: the choice of the sequence.

Authors:  Daniel Vanel
Journal:  Cancer Imaging       Date:  2004-03-23       Impact factor: 3.909

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.