Literature DB >> 7990045

Sorption and solubility of 12 soft denture liners.

F Kawano1, E R Dootz, A Koran, R G Craig.   

Abstract

The long-term stability of a soft denture liner depends to a large extent on the sorption and solubility of the liner. Because sorption and solubility are accompanied by a volumetric change, bacterial infestation, hardening, and color change, it is a physical property of importance. The purpose of this investigation was to determine the sorption and solubility of 12 soft denture liners (Verno-Soft, Super Soft, ProTech, Soft-Pak, Flexor, Novus, Molloplast-B, Durosoft, Justi Soft, Velvesoft, VinaSoft and Prolastic). They include nine copolymers, two silicones and one polyphosphazene fluoroelastomer. The sorption and solubility test was performed as outlined in American Dental Association (ADA) specification 12 for denture base polymers. Five specimens of each material were tested and data were collected at 1 week, 1 month, 3 months, 6 months, and 1 year. Sorption data varied from 0.2 to 5.6 mg/cm2 at 1 week; 0.3 to 12.5 mg/cm2 at 1 month; 0.1 to 22.0 mg/cm2 at 3 months; 0.1 to 13.6 mg/cm2 at 6 months; and 0.1 to 35.7 mg/cm2 at 12 months. Solubility data varied from 0.0 to 0.4 mg/cm2 at 1 week; 0.1 to 0.8 mg/cm2 at 1 month; +0.1 to 1.2 mg/cm2 at 3 months; 0.0 to 1.9 mg/cm2 at 6 months; and +0.2 to 2.3 mg/cm2 at 1 year. A statistical analysis of the data by two-way ANOVA and calculated Tukey intervals showed significant differences between materials at all time intervals. The results of this study have clinical implications because the sorption and solubility may affect the long-term life expectancy of the soft denture liner.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7990045     DOI: 10.1016/0022-3913(94)90559-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

1.  Modified technique of soft liner application.

Authors:  Narendra Gupta; Neeta Misra; Sulabh Kumar; Saurabh Uppal
Journal:  BMJ Case Rep       Date:  2013-02-04

2.  An In-vitro Evaluation of Retention, Colonization and Penetration of Commonly Used Denture Lining Materials By Candida albicans.

Authors:  Sushma Krishnamurthy; Rajendra B Hallikerimath
Journal:  J Clin Diagn Res       Date:  2016-10-01

3.  Time Dependent Effect of a Denture Cleanser on the Sorption and Solubility of Four Soft Liners-An Invitro Study.

Authors:  Swathi Sudhapalli; Sruthikeerthi Sudhapalli
Journal:  J Clin Diagn Res       Date:  2016-04-01

4.  Wettability of denture relining materials under water storage over time.

Authors:  Na-Young Jin; Ho-Rim Lee; Heesu Lee; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

5.  Wettability, water sorption and water solubility of seven silicone elastomers used for maxillofacial prostheses.

Authors:  Anna Karin Hulterström; Anders Berglund; I Eystein Ruyter
Journal:  J Mater Sci Mater Med       Date:  2007-06-28       Impact factor: 3.896

6.  Sorption, solubility, bond strength and hardness of denture soft lining incorporated with silver nanoparticles.

Authors:  Grzegorz Chladek; Jacek Kasperski; Izabela Barszczewska-Rybarek; Jarosław Zmudzki
Journal:  Int J Mol Sci       Date:  2012-12-27       Impact factor: 5.923

Review 7.  Long-Term Soft Denture Lining Materials.

Authors:  Grzegorz Chladek; Jarosław Żmudzki; Jacek Kasperski
Journal:  Materials (Basel)       Date:  2014-08-12       Impact factor: 3.623

8.  Color stability of silicone or acrylic denture liners: an in vitro investigation.

Authors:  Gulfem Ergun; Isil Cekic Nagas
Journal:  Eur J Dent       Date:  2007-07

9.  A comparative evaluation of effect on water sorption and solubility of a temporary soft denture liner material when stored either in distilled water, 5.25% sodium hypochlorite or artificial saliva: An in vitro study.

Authors:  Aditi Garg; K Kamalakanth Shenoy
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

10.  Effect of Monopoly-coating Agent on the Surface Roughness of a Tissue Conditioner Subjected to Cleansing and Disinfection: A Contact Profilometric In vitro Study.

Authors:  Pushkar Gupta; Padma Ariga; Suryakant C Deogade
Journal:  Contemp Clin Dent       Date:  2018-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.