Literature DB >> 7989439

Polymerase chain reaction kinetics when using a positive internal control target to quantitatively detect cytomegalovirus target sequences.

A Chan1, J Zhao, M Krajden.   

Abstract

High-performance liquid chromatography (HPLC) was used to detect and quantify cytomegalovirus (CMV) specific polymerase chain reaction (PCR) products generated during PCR co-amplification. PCR of CMV AD 169 or a plasmid which contains the CMV AD 169 native target sequence using the CMV primer set of Hsia et al. (J. Clin. Microbiol. 27, 1802-1809) generates a 152 bp PCR product. A CMV control sequence plasmid which shared the primer sequence of native CMV AD 169 but when amplified produces a larger 362 bp product was constructed. Under co-amplification conditions there was a linear relationship (over 3 logs) between the molar ratio of input CMV native and control target sequence and the molar ratio of the output PCR products as detected by HPLC despite differences between the two PCR target and product sizes. Co-amplifying known amounts of CMV control sequence plasmid as an internal standard allowed accurate quantitation of the amount of CMV native target sequence in a sample when the two PCR targets were present in approximately equimolar amounts +/- 1.5 log (coefficient of variation (CV) < 12%). By modifying the amount of CMV control target sequence plasmid used for co-amplification, accurate detection of the amount of CMV native sequence in samples could be extended to 5 logs, standard error (S.E.) < or = 16%. Precise quantitation of PCR targets using co-amplification PCR requires multiple sample dilutions to ensure that the CMV native target sequence was in a close equimolar relationship with the CMV control sequence at the time of PCR amplification.

Mesh:

Substances:

Year:  1994        PMID: 7989439     DOI: 10.1016/0166-0934(94)90121-x

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  A highly sensitive assay for detection and quantitation of human cytomegalovirus DNA in serum and plasma by PCR and electrochemiluminescence.

Authors:  R Boom; C Sol; J Weel; Y Gerrits; M de Boer; P Wertheim-van Dillen
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

2.  Detection of cytomegalovirus in blood donors by PCR using the digene SHARP signal system assay: effects of sample preparation and detection methodology.

Authors:  M Krajden; P Shankaran; C Bourke; W Lau
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

3.  Analysis of cAMP RI alpha mRNA expression in breast cancer: evaluation of quantitative polymerase chain reaction for routine use.

Authors:  J M Bartlett; M J Hulme; W R Miller
Journal:  Br J Cancer       Date:  1996-06       Impact factor: 7.640

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.