Literature DB >> 7979837

Surveillance for Legionnaires' disease. Risk factors for morbidity and mortality.

B J Marston1, H B Lipman, R F Breiman.   

Abstract

BACKGROUND: To augment available information about the epidemiology of legionnaires' disease, we analyzed data reported to the passive surveillance system at the Centers for Disease Control and Prevention, Atlanta, Ga, from 1980 through 1989.
METHODS: Risk of disease associated with specific demographic characteristics and health conditions was calculated by comparing the surveillance group with the US population. Risk of death was calculated using multivariate logistic regression models.
RESULTS: A diagnosis of legionnaires' disease was confirmed on the basis of clinical and laboratory criteria for 3254 patients. Disease rates did not vary by year, but were higher in the northern states and during the summer. Legionella pneumophila, serogroup 1, constituted 71.5% of fully identified isolates. This study confirmed previously identified risk factors for legionnaires' disease. In addition, a markedly elevated risk was identified for persons with acquired immunodeficiency syndrome (rate ratio, 41.9; 95% confidence interval, 12.9, 71.0), or hematologic malignancy (rate ratio, 22.4; 95% confidence interval, 19.0, 25.9). Likelihood of death was increased in patients who were elderly or male; those with hospital-acquired infection, renal disease, malignancy, or immunosuppression; and those from whom L pneumophila, serogroup 6, was isolated.
CONCLUSIONS: Infection with Legionella remains an important cause of disease and death in the United States. Diagnosis and treatment of legionnaires' disease should be targeted at patients at increased risk for illness and complications due to Legionella infection. Diagnostic tests for legionnaires' disease based on species other than L pneumophila, serogroup 1, should be developed and tested. Recommendations for prevention of legionnaires' disease should be focused on settings where there are persons at greatest risk for illness or serious outcome.

Entities:  

Mesh:

Year:  1994        PMID: 7979837

Source DB:  PubMed          Journal:  Arch Intern Med        ISSN: 0003-9926


  107 in total

1.  Multiple types of Legionella pneumophila serogroup 6 in a hospital heated-water system associated with sporadic infections.

Authors:  P Visca; P Goldoni; P C Lück; J H Helbig; L Cattani; G Giltri; S Bramati; M Castellani Pastoris
Journal:  J Clin Microbiol       Date:  1999-07       Impact factor: 5.948

2.  Practice guidelines for the management of community-acquired pneumonia in adults. Infectious Diseases Society of America.

Authors:  J G Bartlett; S F Dowell; L A Mandell; T M File; D M Musher; M J Fine
Journal:  Clin Infect Dis       Date:  2000-09-07       Impact factor: 9.079

3.  Roles of interleukin-17 in an experimental Legionella pneumophila pneumonia model.

Authors:  Yoshifumi Kimizuka; Soichiro Kimura; Tomoo Saga; Makoto Ishii; Naoki Hasegawa; Tomoko Betsuyaku; Yoichiro Iwakura; Kazuhiro Tateda; Keizo Yamaguchi
Journal:  Infect Immun       Date:  2011-12-05       Impact factor: 3.441

4.  Windscreen wiper fluid without added screenwash in motor vehicles: a newly identified risk factor for Legionnaires' disease.

Authors:  Anders Wallensten; Isabel Oliver; Katherine Ricketts; George Kafatos; James M Stuart; Carol Joseph
Journal:  Eur J Epidemiol       Date:  2010-06-08       Impact factor: 8.082

5.  Detection of Legionella pneumophila serogroup 1 antigen in bronchoalveolar lavage fluid by an immunochromatographic assay.

Authors:  Peter C Wever; Daan W Notermans; Igor I Tulevski; Jan K M Eeftinck Schattenkerk; Menno D de Jong
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

6.  Sporadic cases of community acquired legionnaires' disease: an ecological study to identify new sources of contamination.

Authors:  D Che; B Decludt; C Campese; J C Desenclos
Journal:  J Epidemiol Community Health       Date:  2003-06       Impact factor: 3.710

7.  Sensitivity of three urinary antigen tests associated with clinical severity in a large outbreak of Legionnaires' disease in The Netherlands.

Authors:  Ed P F Yzerman; Jeroen W den Boer; Kamilla D Lettinga; Joop Schellekens; Jacob Dankert; Marcel Peeters
Journal:  J Clin Microbiol       Date:  2002-09       Impact factor: 5.948

8.  Legionella pneumophila serogroup 4 isolated from joint tissue.

Authors:  Andrea J Linscott; Melinda D Poulter; Kevin Ward; David A Bruckner
Journal:  J Clin Microbiol       Date:  2004-03       Impact factor: 5.948

9.  Legionnaires' Disease in South Africa, 2012-2014.

Authors:  Nicole Wolter; Maimuna Carrim; Cheryl Cohen; Stefano Tempia; Sibongile Walaza; Philip Sahr; Linda de Gouveia; Florette Treurnicht; Orienka Hellferscee; Adam L Cohen; Alvaro J Benitez; Halima Dawood; Ebrahim Variava; Jonas M Winchell; Anne von Gottberg
Journal:  Emerg Infect Dis       Date:  2016-01       Impact factor: 6.883

10.  Occurrence and genetic diversity of uncultured Legionella spp. in drinking water treated at temperatures below 15 degrees C.

Authors:  Bart A Wullings; Dick van der Kooij
Journal:  Appl Environ Microbiol       Date:  2006-01       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.