Literature DB >> 7979723

One-incision approach for insertion of implantable cardioverter defibrillators.

A Markewitz1, H Kaulbach, S Mattke, U Dorwarth, C Weinhold, E Hoffmann, G Steinbeck, B Reichart.   

Abstract

The placement of a transvenous implantable cardioverter defibrillator (ICD) system through a single infraclavicular skin incision has been a surgical goal for years. The development of a new investigational model of ICD with substantially reduced dimensions (volume, 83 cm3; mass, 132 g) has made the one-incision approach a clinical reality. Between March and September 1993, 4 female and 19 male patients (mean age, 60 +/- 9.6 years; range, 46 to 73 years) underwent implantation of this device for the treatment of ventricular fibrillation (n = 14) or ventricular tachycardia (n = 9). One transvenous lead was placed in the right ventricular apex and another in the left subclavian vein. A subpectoral pocket was formed in the infraclavicular area from the same incision to house the ICD generator and, if necessary, the subcutaneous patch. The mean operation time (81.5 +/- 32.7 minutes; range, 54 to 195 minutes) was significantly shorter than that noted for a previous series made up of patients undergoing traditional transvenous ICD implantations. In 20 patients (87%), endovenous defibrillation without a subcutaneous patch successfully caused externally induced ventricular fibrillation to revert with a mean minimum energy output of 21.9 +/- 3.5 J (range, 12 to 24 J). Endovenous defibrillation was more successful when biphasic (n = 16/17 [94%]) shocks rather than monophasic shocks (n = 4/6 [67%]) were used. No mortality, morbidity, or surgical complications were observed. These results indicate that the one-incision approach and the small size of the ICD generator can substantially facilitate ICD implantation and result in a reduction in the surgical trauma, the operation time, and the amount of material implanted.

Entities:  

Mesh:

Year:  1994        PMID: 7979723     DOI: 10.1016/0003-4975(94)91643-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Submuscular versus subcutaneous pectoral implantation of cardioverter-defibrillators: effect on high voltage pathway impedance and defibrillation efficacy.

Authors:  D Iskos; K Lock; K G Lurie; G J Fahy; S Petersen-Stejskal; D G Benditt
Journal:  J Interv Card Electrophysiol       Date:  1998-03       Impact factor: 1.900

2.  Subpectoral implantation of a cardioverter defibrillator under local anaesthesia.

Authors:  K J Lipscomb; N J Linker; A P Fitzpatrick
Journal:  Heart       Date:  1998-03       Impact factor: 5.994

3.  Subpectoral cardioverter-defibrillator implantation using a lateral approach.

Authors:  X F Costeas; P G Strembelas; D X Markou; C I Stefanadis; P K Toutouzas
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

  3 in total