Literature DB >> 7978523

Deformation of metal brackets: a comparative study.

D A Flores1, L K Choi, J M Caruso, J L Tomlinson, G E Scott, M T Jeiroudi.   

Abstract

The purpose of this study was to determine the effect of material and design on the force and stress required to permanently deform metal brackets. Fourteen types of metal brackets were categorized according to raw material composition, slot torque degree, and wing type. Five types of raw materials, three types of slot torque degree, and four types of wing design were tested using an archwire torque test developed by Flores. An analysis of variance (ANOVA) and t-test showed that all three categories had a significant effect on the force and stress needed to permanently deform metal brackets. Of the three, raw material had the greatest effect on the amount of force. Results showed that 17-4PH and 303S had higher yield strengths and regular twin brackets had higher resistance to deformation. Also, as slot torque degree increased, brackets deformed with less force. Result confirmed that brackets requiring the greatest stress to permanently deform were made of steel with the greatest hardness.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7978523     DOI: 10.1043/0003-3219(1994)064<0283:DOMBAC>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  5 in total

1.  Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Authors:  Ryan A Lacoursiere; David S Nobes; Darren L N Homeniuk; Jason P Carey; Hisham H Badawi; Paul W Major
Journal:  J Dent Biomech       Date:  2009-12-13

2.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

3.  Are torque values of preadjusted brackets precise?

Authors:  Alessandra Motta Streva; Flávio Augusto Cotrim-Ferreira; Daniela Gamba Garib; Paulo Eduardo Guedes Carvalho
Journal:  J Appl Oral Sci       Date:  2011-05-27       Impact factor: 2.698

4.  Three-dimensional deformation of orthodontic brackets.

Authors:  Garrett W Melenka; David S Nobes; Paul W Major; Jason P Carey
Journal:  J Dent Biomech       Date:  2013-06-06

5.  Evaluation of Time Consumption for Debonding Brackets Using Different Techniques: A Hospital-Based Study.

Authors:  Neelutpal Bora; Putul Mahanta; Ranjumoni Konwar; Bharati Basumatari; Chiranjita Phukan; Deepjyoti Kalita; Senjam Gojendra Singh; Sangeeta Deka
Journal:  J Healthc Eng       Date:  2021-08-24       Impact factor: 2.682

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.