Literature DB >> 7978474

Noninvasive, continuous blood pressure measurement by arterial tonometry during anesthesia in children.

O Kemmotsu1, M Ohno, K Takita, H Sugimoto, H Otsuka, Y Morimoto, T Mayumi.   

Abstract

BACKGROUND: The authors' previous study of arterial tonometry in children demonstrated poor agreement of tonometric blood pressure (TBP) measurements with intraarterial blood pressure (IBP) measurements. The aim of the current study is to evaluate the feasibility of TBP measurements in children aged 1-6 yr using a newly designed pediatric sensor housing, by comparing TBP values with values obtained by IBP measurements.
METHODS: Thirty-four children (aged 1-6 yr, ASA physical status 1-2) were studied undergoing elective abdominal or urologic surgery under general anesthesia. A 22- or 24-G cannula was inserted into the right radial artery. A TBP sensor housing was positioned over the left radial artery. TBP and IBP were continuously monitored and data were periodically sampled during and after intubation, during surgery, and during the recovery period.
RESULTS: TBP waveforms were similar to those of IBP. Limits of agreement (bias +/- 2 SD) were 12 and -13.3 mmHg for systolic, 11.6 and -10.4 mmHg for mean, and 13.2 and -10.8 mmHg for diastolic pressures for 3,400 paired points. Measurements could not be made in ten children because of insufficient pulse contour.
CONCLUSIONS: When pulse contour is sufficient for analysis, TBP monitoring provides an apparently safe and accurate method for the continuous measurement of arterial blood pressure during anesthesia in children aged 1-6 yr.

Entities:  

Mesh:

Year:  1994        PMID: 7978474     DOI: 10.1097/00000542-199411000-00009

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  4 in total

Review 1.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

2.  Cerebral autoregulation improves in epilepsy patients after temporal lobe surgery.

Authors:  Matthias Dütsch; Orrin Devinsky; Werner Doyle; Harald Marthol; Max J Hilz
Journal:  J Neurol       Date:  2004-10       Impact factor: 4.849

Review 3.  Blood pressure monitoring in sleep: time to wake up.

Authors:  Younghoon Kwon; Patrick L Stafford; Diane C Lim; Sungha Park; Sung-Hoon Kim; Richard B Berry; David A Calhoun
Journal:  Blood Press Monit       Date:  2020-04       Impact factor: 1.430

4.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.