Literature DB >> 7977093

Usefulness of a third Holter lead for detection of myocardial ischemia.

G A Lanza1, M Mascellanti, M Placentino, M Lucente, F Crea, A Maseri.   

Abstract

Two-channel ambulatory electrocardiographic (ECG) monitoring is a useful method for detecting transient myocardial ischemia in patients with coronary artery disease. However, the monitoring of only 2 leads may fail to detect a significant number of ischemic episodes. In this study, the additional diagnostic value of a third bipolar chest lead was evaluated by recording a simultaneous 12-lead electrocardiogram and a 3-channel ambulatory electrocardiogram during exercise testing in 223 patients (aged 63 +/- 10 years) with proved or suspected coronary disease. Leads CM5, CM3, and an inferior lead (Y-modified or CMf) were monitored on the ambulatory electrocardiogram. Diagnostic ST-segment depression on the standard electrocardiogram was detected in 98 patients (44%), 94 (96%) of whom also had diagnostic ST-segment changes on the ambulatory electrocardiogram. Two additional patients had ST-segment depression only on the ambulatory electrocardiogram (both in lead CM5). Maximal ST-segment depression and duration of ischemia detected on standard and ambulatory ECG leads were similar in the 94 patients in whom ST-segment changes were detected on both types of ECG monitoring. CM5 was the single lead with the highest sensitivity (89%) in detecting myocardial ischemia. The addition of CM3 to CM5 increased sensitivity to 91%, and the addition of an inferior lead to CM5 increased sensitivity to 94%, particularly improving the detection of isolated inferior myocardial ischemia. The combination of all 3 ambulatory ECG leads had a sensitivity of 96%, an improvement of only 2% compared with the best combination of 2 leads (i.e., CM5 +/- inferior lead).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7977093     DOI: 10.1016/0002-9149(94)90551-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

Review 1.  ST-segment analysis in ambulatory ECG (AECG or Holter) monitoring in patients with coronary artery disease: clinical significance and analytic techniques.

Authors:  Peter H Stone
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-04       Impact factor: 1.468

2.  Myocardial Ischemia Induced by 5-Fluorouracil: A Prospective Electrocardiographic and Cardiac Biomarker Study.

Authors:  Merete Vaage-Nilsen; Dorte L Nielsen; Anne Dyhl-Polk; Morten Schou; Kirsten K Vistisen; Anne-Sophie Sillesen; Eva Serup-Hansen; Jens Faber; Tobias W Klausen; Stig E Bojesen
Journal:  Oncologist       Date:  2020-10-07

3.  Air pollution and ST-segment depression in elderly subjects.

Authors:  Diane R Gold; Augusto A Litonjua; Antonella Zanobetti; Brent A Coull; Joel Schwartz; Gail MacCallum; Richard L Verrier; Bruce D Nearing; Marina J Canner; Helen Suh; Peter H Stone
Journal:  Environ Health Perspect       Date:  2005-07       Impact factor: 9.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.