Fixation of closed metacarpal shaft fractures. Transverse K-wires in 22 cases.

A S Paul1, N Kurdy, P R Kay.   

Abstract

22 patients who had closed displaced metacarpal shaft fractures, treated by transverse percutaneous K-wire fixation were reviewed. In 11 cases, 1 distal and 1 proximal wire were inserted and in the rest, 2 distal and 1 proximal wire were used. The results in patients treated with a single distal wire were unsatisfactory due to pivoting of the distal fragment on the wire with consequent angulation and cosmetic deformity. In those who had 2 wires inserted distally, the reduction position was maintained throughout.

Entities:  

Mesh:

Year:  1994        PMID: 7976290     DOI: 10.3109/17453679408995485

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  4 in total

1.  Anatomic Assessment of K-Wire Trajectory for Transverse Percutaneous Fixation of Small Finger Metacarpal Fractures: A Cadaveric Study.

Authors:  Louis C Grandizio; Amy Speeckaert; Zach Kozick; Joel C Klena
Journal:  Hand (N Y)       Date:  2017-02-14

2.  A Comparison of Locking Plates and Intramedullary Pinning for Fixation of Metacarpal Shaft Fractures.

Authors:  Daniel Dreyfuss; Raviv Allon; Nufar Izacson; Dan Hutt
Journal:  Hand (N Y)       Date:  2018-09-07

Review 3.  Open reduction and internal fixation versus percutaneous transverse Kirschner wire fixation for single, closed second to fifth metacarpal shaft fractures: a systematic review.

Authors:  A P A Greeven; S Bezstarosti; P Krijnen; I B Schipper
Journal:  Eur J Trauma Emerg Surg       Date:  2015-03-14       Impact factor: 3.693

4.  The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures.

Authors:  Suk-Ho Moon; Hak-Soo Kim; Sung-No Jung; Ho Kwon
Journal:  Arch Plast Surg       Date:  2016-03-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.