Literature DB >> 7975331

Contrast thresholds for stereoscopic depth identification with isoluminant and isochromatic stimuli.

D R Simmons1, F A Kingdom.   

Abstract

Contrast thresholds for stereoscopic depth identification (crossed or uncrossed) were measured as a function of disparity using isoluminant (red-green) and isochromatic (yellow-black) 0.5 c/deg Gabor patches. For the purposes of comparison stimulus contrasts were scaled by their respective detection thresholds. The detection thresholds employed were computed from the monocular detection thresholds of the stereo half-images, based on the assumption that simultaneous detection of these half-images in each eye was a sufficient condition for stereopsis. It was found that the disparity tuning of both chromatic and luminance mechanisms was similar, with a performance peak for a binocular phase disparity of 50-120 deg. However, more contrast was required, relative to detection threshold, for the chromatic patterns to evoke a sensation of stereoscopic depth. These results suggest that stereopsis in the absence of luminance cues is supported by a less-contrast-sensitive analogue of the system that supports stereopsis in the presence of luminance cues. The results are also consistent with there being a lower density of disparity-selective mechanisms in the chromatic pathway. The implications of these data for previous studies of stereopsis at isoluminance is discussed.

Mesh:

Year:  1994        PMID: 7975331     DOI: 10.1016/0042-6989(94)90269-0

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  5 in total

1.  DLP-based dichoptic vision test system.

Authors:  Russell L Woods; Henry L Apfelbaum; Eli Peli
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

2.  Binocular contrast summation and inhibition depends on spatial frequency, eccentricity and binocular disparity.

Authors:  Concetta F Alberti; Peter J Bex
Journal:  Ophthalmic Physiol Opt       Date:  2018-09-16       Impact factor: 3.117

3.  Effect of chromatic contrast on stereoacuity measurement with computer-aided three-dimensional technology.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  Ann Transl Med       Date:  2019-05

4.  Orientation tuning of binocular summation: a comparison of colour to achromatic contrast.

Authors:  Mina Gheiratmand; Avital S Cherniawsky; Kathy T Mullen
Journal:  Sci Rep       Date:  2016-05-11       Impact factor: 4.379

5.  The difference of distance stereoacuity measured with different separating methods.

Authors:  Lingzhi Zhao; Yu Zhang; Huang Wu; Jun Xiao
Journal:  Ann Transl Med       Date:  2020-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.