Effects of electrical stimulation on lymphatic flow and limb volume in the rat.

H A Cook1, M Morales, E M La Rosa, J Dean, M K Donnelly, P McHugh, A Otradovec, K S Wright, T Kula, S H Tepper.   

Abstract

BACKGROUND AND
PURPOSE: The mechanism by which electrical stimulation affects edema has not been elucidated. The purpose of this study was to determine whether subcontraction high-voltage stimulation (SC-HVS) (ie, electrical stimulation that did not elicit a visible contraction) applied to the right hind limbs of rats would (1) alter the rate of lymphatic uptake of injected albumin labeled with Evans blue dye (AL-EBD) and (2) affect experimentally induced edema. SUBJECTS AND METHODS: The paws of 28 anesthetized Sprague-Dawley rats (mean weight = 263 g, SD = 48 g) were injected with AL-EBD. The experimental group (n = 13) received 1 hour of SC-HVS, and the control group (n = 15) received sham treatment consisting of the same treatment administered to the experimental group but without the SC-HVS. Blood samples and volume measurements were obtained at intervals over a 7-hour period.
RESULTS: Analysis of variance and post hoc testing indicated that higher amounts of AL-EBD were taken up by the lymph of the experimental group animals as compared with the control group animals at each time period following the treatment. The experimental group's AL-EBD reached significance immediately after treatment, whereas the control group required an additional 4 hours. There was no significant reduction in limb volume in either group. CONCLUSION AND DISCUSSION: The SC-HVS significantly increased the uptake of AL-EBD by lymphatic vessels, but it did not cause a significant decrease in the induced edema. The results of this study indicate that SC-HVS has the potential to reduce edema by increasing lymphatic uptake of proteins.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7972365     DOI: 10.1093/ptj/74.11.1040

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  4 in total

1.  Effect of high-voltage electrical stimulation on the albumin and histamine serum concentrations, edema, and pain in acute joint inflammation of rats.

Authors:  Maria C Sandoval; Carolina R Ramirez; Diana M Camargo; Thiago L Russo; Tania F Salvini
Journal:  Braz J Phys Ther       Date:  2015-04-27       Impact factor: 3.377

Review 2.  Effects and mechanisms of a microcurrent dressing on skin wound healing: a review.

Authors:  Chao Yu; Zong-Qian Hu; Rui-Yun Peng
Journal:  Mil Med Res       Date:  2014-11-24

3.  Synergistic effects of Combined Therapy: nonfocused ultrasound plus Aussie current for noninvasive body contouring.

Authors:  Vivianne Carvalho Canela; Cinthia Nicoletti Crivelaro; Luciane Zacchi Ferla; Gisele Marques Pelozo; Juliana Azevedo; Richard Eloin Liebano; Caroline Nogueira; Renata Michelini Guidi; Clóvis Grecco; Estela Sant'Ana
Journal:  Clin Cosmet Investig Dermatol       Date:  2018-04-27

4.  Effects of Acute Microcurrent Electrical Stimulation on Muscle Function and Subsequent Recovery Strategy.

Authors:  Alessandro Piras; Lorenzo Zini; Aurelio Trofè; Francesco Campa; Milena Raffi
Journal:  Int J Environ Res Public Health       Date:  2021-04-26       Impact factor: 3.390