Literature DB >> 7971708

An improved microscope stage for direct observation of freezing and freeze drying.

S L Nail1, L M Her, C P Proffitt, L L Nail.   

Abstract

A microscope stage for observation of freezing and freeze drying is described. The stage uses thermoelectric (Peltier) heaters configured in two stages, with circulating fluid as a heat sink on the high temperature side. Lowest attainable sample temperature is about -47 degrees C. Principal advantages of this system are closed-loop control of stage temperature, rapid response to changes in temperature set point, and improved documentation of experiments by use of a video recorder system with a character generator which allows display of sample identity and temperature. Accuracy of measuring the sample temperature in the field of view was validated by comparing observed values of eutectic melting with published values for a series of solutes with eutectic temperatures in the range from -2 degrees C to -32 degrees C. Good agreement was obtained throughout this range.

Mesh:

Year:  1994        PMID: 7971708     DOI: 10.1023/a:1018972428858

Source DB:  PubMed          Journal:  Pharm Res        ISSN: 0724-8741            Impact factor:   4.200


  4 in total

1.  APPARATUS FOR MICROSCOPIC OBSERVATIONS DURING FREEZE-DRYING (AFBR FREEZE-DRYING MICROSCOPE MODEL 2).

Authors:  A P MACKENZIE
Journal:  Biodynamica       Date:  1964-11

2.  Measurement of glass transition temperatures of freeze-concentrated solutes by differential scanning calorimetry.

Authors:  L M Her; S L Nail
Journal:  Pharm Res       Date:  1994-01       Impact factor: 4.200

3.  Physical chemistry of freeze-drying: measurement of sublimation rates for frozen aqueous solutions by a microbalance technique.

Authors:  M J Pikal; S Shah; D Senior; J E Lang
Journal:  J Pharm Sci       Date:  1983-06       Impact factor: 3.534

4.  Two simple freeze drying microscope stages.

Authors:  J M Flink; F Gejl-Hansen
Journal:  Rev Sci Instrum       Date:  1978-02       Impact factor: 1.523

  4 in total
  4 in total

1.  Characterization of murine monoclonal antibody to tumor necrosis factor (TNF-MAb) formulation for freeze-drying cycle development.

Authors:  X Ma; D Q Wang; R Bouffard; A MacKenzie
Journal:  Pharm Res       Date:  2001-02       Impact factor: 4.200

2.  Precise and millidegree stable temperature control for fluorescence imaging: application to phase transitions in lipid membranes.

Authors:  Elaine R Farkas; Watt W Webb
Journal:  Rev Sci Instrum       Date:  2010-09       Impact factor: 1.523

3.  Phase transitions of glycine in frozen aqueous solutions and during freeze-drying.

Authors:  A Pyne; R Suryanarayanan
Journal:  Pharm Res       Date:  2001-10       Impact factor: 4.200

4.  Glycine crystallization during freezing: the effects of salt form, pH, and ionic strength.

Authors:  M J Akers; N Milton; S R Byrn; S L Nail
Journal:  Pharm Res       Date:  1995-10       Impact factor: 4.200

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.