Use of Memokath, a second generation urethral stent for relief of urinary retention in male spinal cord injured patients.

B M Soni1, S Vaidyanatham, K R Krishnan.   

Abstract

Memokath (Engineers & Doctors A/S, Hornbaek, Denmark) a second generation urethral stent composed of titanium nickel alloy with shape memory effect was deployed in 10 male spinal cord injured patients with urinary retention. The stent was inserted under sterile conditions via a delivery catheter under fluoroscopic control in seven and with the aid of a flexible cytoscope in three. The proximal end of the stent was positioned at the bladder neck and 50 ml of normal saline at 45 degrees C was flushed through the stent which resulted in expansion of the distal most four coils of the stent in the proximal bulbar urethra; thus the internal sphincter (bladder neck) and external sphincter zone were kept open by the stent. Urethral stenting helped to achieve complete vesical emptying in all 10 patients. The complications included transient autonomic dysreflexia in two, transient urinary retention due to blood clot in one, and acute urinary tract infection in one patient. With a follow up of 3-7 months, all 10 patients have been asymptomatic, with residual urine of less than 50 ml. There has been no migration or blocking of the stent. However, these stents require replacement at 12-18 months, but it is a short procedure as the Memokath, when cooled with saline at 4 degrees C, becomes supersoft, enabling its easy and nontraumatic removal.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7970850     DOI: 10.1038/sc.1994.76

Source DB:  PubMed          Journal:  Paraplegia        ISSN: 0031-1758


  3 in total

1.  Long-term result of Memokath urethral sphincter stent in spinal cord injury patients.

Authors:  Subramanian Vaidyanathan; Bakul M Soni; Tun Oo; Pradipkumar Sett; Peter L Hughes; Gurpreet Singh
Journal:  BMC Urol       Date:  2002-11-11       Impact factor: 2.264

2.  Thermo-expandable metallic urethral stents for managing recurrent bulbar urethral strictures: To use or not?

Authors:  Mohamed M Abdallah; Mohamed Selim; Tarek Abdelbakey
Journal:  Arab J Urol       Date:  2013-01-23

3.  Early experience with a thermo-expandable stent (memokath) for the management of recurrent urethral stricture.

Authors:  Hyun Su Jung; Joon Woo Kim; Jun Nyung Lee; Hyun Tae Kim; Eun Sang Yoo; Bum Soo Kim
Journal:  Korean J Urol       Date:  2013-12-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.