Effects of digital resolution on characterisation of cardiac late potentials.

O Svensson1, L Sörnmo, O Pahlm.   

Abstract

The effects of amplitude resolution in the signal-averaged ECG are studied in relation to the analysis of cardiac late potentials. The statistical properties of ECG signals from 22 patients after myocardial infarction were investigated in terms of amplitude distribution and noise level for the material. It was found that unbiased averaging could be achieved using a resolution greater than 10 microV. The noise levels of the bandpass-filtered individual X, Y and Z leads (range of 1-10 microV) and the vector magnitude were also investigated. Marked intra-lead differences in noise level were found, indicating that analysis based on individual leads is preferable. The effects of quantisation noise on the vector magnitude were negligible for amplitude resolutions below 5 microV. However, the additional noise contribution at 5 microV could be compensated by a moderate increase in acquisition time. The sensitivity to noise was considered when determining the endpoint of the filtered QRS complex using the vector magnitude.

Entities:  

Mesh:

Year:  1994        PMID: 7967846     DOI: 10.1007/BF02523321

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  An accurate, clinically practical system for spatial vectorcardiography.

Authors:  E FRANK
Journal:  Circulation       Date:  1956-05       Impact factor: 29.690

Review 2.  Standards for analysis of ventricular late potentials using high resolution or signal-averaged electrocardiography. A statement by a Task Force Committee between the European Society of Cardiology, the American Heart Association and the American College of Cardiology.

Authors:  G Breithardt; M E Cain; N el-Sherif; N Flowers; V Hombach; M Janse; M B Simson; G Steinbeck
Journal:  Eur Heart J       Date:  1991-04       Impact factor: 29.983

3.  Detection of late potentials by adaptive filtering.

Authors:  L Y Shelton; G G Cano; D A Coast; S A Briller
Journal:  J Electrocardiol       Date:  1990       Impact factor: 1.438

4.  A prospective evaluation of the immediate reproducibility of the signal-averaged ECG.

Authors:  P T Sager; J Widerhorn; M Pascual; C Leon; S H Rahimtoola; A K Bhandari
Journal:  Am Heart J       Date:  1991-06       Impact factor: 4.749

5.  Influence of noise on the analysis of late potentials.

Authors:  O Svensson; L Sörnmo; O Pahlm
Journal:  J Electrocardiol       Date:  1992       Impact factor: 1.438

6.  Importance of the endpoint of noise reduction in analysis of the signal-averaged electrocardiogram.

Authors:  J S Steinberg; J T Bigger
Journal:  Am J Cardiol       Date:  1989-03-01       Impact factor: 2.778

7.  The analysis of ventricular late potentials using orthogonal recordings.

Authors:  P Lander; R B Deal; E J Berbari
Journal:  IEEE Trans Biomed Eng       Date:  1988-08       Impact factor: 4.538

8.  Roundoff errors in signal averaging systems.

Authors:  R P Gaumond
Journal:  IEEE Trans Biomed Eng       Date:  1986-03       Impact factor: 4.538

9.  Noninvasive beat-by-beat registration of ventricular late potentials using high resolution electrocardiography.

Authors:  V Hombach; U Kebbel; H W Höpp; U Winter; H Hirche
Journal:  Int J Cardiol       Date:  1984-08       Impact factor: 4.164

10.  Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction.

Authors:  M B Simson
Journal:  Circulation       Date:  1981-08       Impact factor: 29.690

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.