Biomechanical assessment of below-knee residual limb tissue.

A F Mak1, G H Liu, S Y Lee.   

Abstract

In vivo indentation properties of the residual limb tissues of a group of senior subjects with below-knee (BK) amputation were measured and compared with those of nondisabled young adults. It was found that differences attributable to site variations, states of muscular activity, and the differences between the nondisabled young group and the group consisting of the seniors with amputation were all noted to be highly significant statistically. However, paired comparison between the residual limb and the sound contralateral limb of the senior group showed no significant difference. Residual limb properties measured right before the first prosthetic measurements and fittings and those measured at the first outpatient follow-up were found to be slightly different.

Entities:  

Mesh:

Year:  1994        PMID: 7965877

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  8 in total

1.  Assessment of neck tissue fibrosis using an ultrasound palpation system: a feasibility study.

Authors:  Y P Zheng; S F Leung; A F Mak
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

2.  Estimation of Young's modulus and Poisson's ratio of soft tissue from indentation using two different-sized indentors: finite element analysis of the finite deformation effect.

Authors:  A P C Choi; Y P Zheng
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

3.  Extraction of mechanical properties of foot plantar tissues using ultrasound indentation associated with genetic algorithm.

Authors:  Hang-Yin Ling; Pong-Chi Choi; Yong-ping Zheng; Kin-Tak Lau
Journal:  J Mater Sci Mater Med       Date:  2007-05-05       Impact factor: 3.896

4.  Modeling and preliminary testing socket-residual limb interface stiffness of above-elbow prostheses.

Authors:  Jonathon W Sensinger; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-04       Impact factor: 3.802

Review 5.  Indentation versus tensile measurements of Young's modulus for soft biological tissues.

Authors:  Clayton T McKee; Julie A Last; Paul Russell; Christopher J Murphy
Journal:  Tissue Eng Part B Rev       Date:  2011-03-21       Impact factor: 6.389

6.  A simulation-based analysis of the effects of variable prosthesis stiffness on interface dynamics between the prosthetic socket and residual limb.

Authors:  Michael A McGeehan; Peter G Adamczyk; Kieran M Nichols; Michael E Hahn
Journal:  J Rehabil Assist Technol Eng       Date:  2022-07-15

7.  Effect of Local Neck Anatomy on Localized One-Dimensional Measurements of Arterial Stiffness: A Finite-Element Model Study.

Authors:  Adriaan Campo; Matthew D McGarry; Thomas Panis; Joris Dirckx; Elisa Konofagou
Journal:  J Biomech Eng       Date:  2019-03-01       Impact factor: 2.097

8.  Template models for simulation of surface manipulation of musculoskeletal extremities.

Authors:  Sean Doherty; Ben Landis; Tammy M Owings; Ahmet Erdemir
Journal:  PLoS One       Date:  2022-08-15       Impact factor: 3.752

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.