Literature DB >> 7961072

Clinical and radiographic results of total hip arthroplasty in dogs: 96 cases (1986-1992).

B J Massat1, P B Vasseur.   

Abstract

Results of total hip arthroplasty in 84 dogs (96 hips) were evaluated. Eight (9.5%) of the 84 dogs developed 1 or more complications after total hip arthroplasty. Complications resolved or were corrected in 4 of the dogs; all 4 ultimately achieved good or excellent hip function. Complications necessitated removal of the prosthesis in the other 4 dogs; 3 ultimately achieved fair hip function and 1 had only poor hip function. Therefore, after resolution of complications, 96% of the hips had good or excellent function. Force plate analysis was performed on 6 dogs with excellent hip function; peak vertical force for the limb that had been operated on was greater than or equal to peak vertical force for the contralateral limb. Radiographically, a radiolucent zone was visible around the acetabular component in 89% of the hips and around the femoral component in 26%. The radiolucent zone around the acetabular and femoral components widened in 14% (6 of 43) and 27% (3 of 11), respectively, of the hips with adequate radiographic follow-up. Aseptic loosening of the acetabular component developed in 3 (3%) of 96 hips; one was successfully revised. Aseptic loosening of the femoral component was not apparent in any of the dogs in this study. Other complications included femoral fracture (n = 3), neurapraxia (3), luxation (1), and unexplained lameness that required implant removal (1). None of the dogs had evidence of wound infection.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7961072

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  4 in total

1.  Cemented total hip replacement as a method of treating coxofemoral arthritis.

Authors:  V J Barkowski; N A Embleton; A L Wilson
Journal:  Can Vet J       Date:  1997-12       Impact factor: 1.008

2.  Modular hybrid total hip arthroplasty. Experimental study in dogs.

Authors:  Bruno W Minto; Cláudia Valéria S Brandão; Gilberto J C Pereira; Daniela Campagnol; Maria Jaqueline Mamprim; Carlos Roberto Padovani; José J T Ranzani
Journal:  Acta Vet Scand       Date:  2011-07-07       Impact factor: 1.695

3.  Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement.

Authors:  Ching-Ho Wu; Cheng-Chung Lin; Tung-Wu Lu; Sheng-Mao Hou; Chih-Chung Hu; Lih-Seng Yeh
Journal:  Biomed Eng Online       Date:  2013-11-10       Impact factor: 2.819

4.  Greater trochanter morphology and association with patient demographics, surgical factors, and post-operative stem position: a retrospective assessment of 150 cementless THRs in 135 dogs.

Authors:  Catrina J Silveira; Katherine H Barnes; Sharon C Kerwin; W Brian Saunders
Journal:  BMC Vet Res       Date:  2022-02-23       Impact factor: 2.741

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.