The shape of the arterial pressure waveform is a non-linear function of stroke volume, heart rate and many other cardiovascular parameters. Previous attempts have been made to exploit this relationship and derive cardiac output (CO) from the arterial pressure waveform. These classical "pulse-contour" methods utilized simplifying linear assumptions, as a result they failed to adequately estimate CO over a sufficiently wide range of hemodynamic conditions. We have applied pattern recognition and image processing techniques to the problem of deriving CO from the arterial pressure waveform, thereby eliminating the need for simplifying assumptions. Computer simulations were used to develop the basic pattern recognition algorithms and compare their performance with that of published classical "pulse-contour" methods. Animal models were subsequently used to demonstrate proof of the concept. For over 200,000 individual heart beats, covering a wide range of hemodynamic conditions, the mean error, in calculated CO compared to ultrasonic flow probe determined CO, was 2.8% with a standard deviation of 9.8%.

Entities:  

Mesh:

Year:  1994        PMID: 7959797     DOI: 10.1109/10.324522

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

Review 1.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

2.  Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal.

Authors:  Nima Fazeli; Jin-Oh Hahn
Journal:  Front Physiol       Date:  2012-07-25       Impact factor: 4.566

3.  Temporally coherent cardiac motion tracking from cine MRI: Traditional registration method and modern CNN method.

Authors:  Mengyun Qiao; Yuanyuan Wang; Yi Guo; Lu Huang; Liming Xia; Qian Tao
Journal:  Med Phys       Date:  2020-07-06       Impact factor: 4.071

4.  Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters.

Authors:  Charles Carlson; Vanessa-Rose Turpin; Ahmad Suliman; Carl Ade; Steve Warren; David E Thompson
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

5.  A Novel Pulse Measurement System by Using Laser Triangulation and a CMOS Image Sensor.

Authors:  Jih-Huah Wu; Rong-Seng Chang; Joe-Air Jiang
Journal:  Sensors (Basel)       Date:  2007-12-19       Impact factor: 3.576

6.  Relationship between stroke volume and pulse pressure during blood volume perturbation: a mathematical analysis.

Authors:  Ramin Bighamian; Jin-Oh Hahn
Journal:  Biomed Res Int       Date:  2014-05-20       Impact factor: 3.411