Electrical impedance measured changes in thoracic fluid content during thoracentesis.

J R Petersen1, B V Jensen, H Drabaek, K Viskum, J Mehlsen.   

Abstract

In patients (seven females and 11 males) with pleural effusion due to pulmonary (n = 13) or cardiac disease (n = 5) the change in baseline transthoracic impedance (Z0) was measured by electrical impedance (BoMed's NCCOM-3, 70 kHz) during thoracentesis. Data were obtained before and after withdrawal of each 500 ml, and at the end of the thoracentesis. We found a close linear correlation (r = 0.97) between changes in Z0 and the volume of aspirated pleural effusion (y = 0.415.x+0.093). The variability of the estimated thoracic fluid volumes was analysed with a plot of the residuals from the regression line, and we found that changes in thoracic fluid volume estimated by impedance technique would be within +/- 302 ml (= 2 SD). However, the absolute value of Z0 before thoracentesis could not differentiate the group of patients with pleural effusion from normal subjects (n = 28).

Entities:  

Mesh:

Year:  1994        PMID: 7955943     DOI: 10.1111/j.1475-097x.1994.tb00404.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  6 in total

1.  Influence of combined exercise and gravity transients and apnea on hemodynamics.

Authors:  Uwe Hoffmann; Tobias Dräger; Ansgar Steegmanns; Thomas Koesterer; Dag Linnarsson
Journal:  Eur J Appl Physiol       Date:  2009-04-09       Impact factor: 3.078

Review 2.  Impedance cardiography: more questions than answers.

Authors:  David J Wang; Stephen S Gottlieb
Journal:  Curr Heart Fail Rep       Date:  2006-09

Review 3.  Haemodynamic monitoring in acute heart failure.

Authors:  Maurizio Cecconi; Toby E Reynolds; Nawaf Al-Subaie; Andrew Rhodes
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.214

Review 4.  Impedance cardiography: more questions than answers.

Authors:  David J Wang; Stephen S Gottlieb
Journal:  Curr Cardiol Rep       Date:  2006-05       Impact factor: 2.931

5.  Feasibility of bioelectrical impedance spectroscopy measurement before and after thoracentesis.

Authors:  Matthias Daniel Zink; Sören Weyer; Karolin Pauly; Andreas Napp; Michael Dreher; Steffen Leonhardt; Nikolaus Marx; Patrick Schauerte; Karl Mischke
Journal:  Biomed Res Int       Date:  2015-03-11       Impact factor: 3.411

6.  Segmental Bioelectrical Impedance Spectroscopy to Monitor Fluid Status in Heart Failure.

Authors:  Matthias Daniel Zink; Fabienne König; Sören Weyer; Klaus Willmes; Steffen Leonhardt; Nikolaus Marx; Andreas Napp
Journal:  Sci Rep       Date:  2020-02-27       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.