Literature DB >> 7955303

High-frequency ultrasound corneal pachymetry in the assessment of corneal scars for therapeutic planning.

D Z Reinstein1, I M Aslanides, R H Silverman, P A Asbell, D J Coleman.   

Abstract

We used high-frequency ultrasound B-scanning with digital signal processing for pachymetric analysis of corneal scars to help determine the optimal management strategy. Four patients were selected for this report. By an automated motor system, 12 consecutive, parallel ultrasound B-scans, each 2.5 to 3 mm wide at 0.25 mm intervals, were obtained from the central corneal area of three patients with anterior corneal scarring. In a fourth patient with near complete corneal scarring obscuring the view of the anterior chamber, a set of 15 mm wide B-scans was obtained. Digitized ultrasound signals were used to produce high-resolution images and I-scans enabling a pachymetric precision of +/- 2 microns (SD). Epithelial, scar, and corneal thickness measurements were made along each scan to determine the most significant zone of pathology. Pachymetry of the cornea and the individual layers was used to assess the suitability for either photorefractive or penetrating keratectomy. B-scan imaging of the full anterior segment provided useful information for the preoperative planning of anterior segment reconstruction and the prognostic evaluation of penetrating keratoplasty. This method provides a powerful tool for the corneal surgeon in management planning.

Entities:  

Mesh:

Year:  1994        PMID: 7955303     DOI: 10.1097/00140068-199407000-00014

Source DB:  PubMed          Journal:  CLAO J        ISSN: 0733-8902


  4 in total

1.  High frequency ultrasound imaging in pupillary block glaucoma.

Authors:  I M Aslanides; P E Libre; R H Silverman; D Z Reinstein; D R Lazzaro; M J Rondeau; G K Harmon; D J Coleman
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

2.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

Review 3.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

4.  Phototherapeutic keratectomy: Indications, methods and decision making.

Authors:  Rashmi Deshmukh; Jagadesh C Reddy; Christopher J Rapuano; Pravin K Vaddavalli
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.