A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups.

Z M Jin1, D Dowson, J Fisher.   

Abstract

It is well known that the wear factor for ultra-high molecular weight polyethylene (UHMWPE) sliding on metallic or ceramic counterfaces is largely independent of contact stress for modest loading conditions and sliding distances. However, it is now recognized that under more severe stress levels and with sliding distances comparable to those encountered in current replacement synovial joints, subsurface fatigue contributes to the volume of wear debris. Since the fatigue process is influenced by surface stress levels it is becoming increasingly important to limit the contact stress through design in order to minimize the volume of UHMWPE wear debris in implants. The contact pressure in UHMWPE acetabular cups has been predicted using both the simple elasticity analysis and the finite element method. It has been shown that the radial clearance between the femoral head and the socket is the dominant parameter in determining the contact stress. Thus, the radial clearance should be controlled so the contact half width is close to the femoral head radius (a total included angle of contact of 120 degrees) to minimize the contact pressure. There is little benefit to be gained by increasing the contact half width greater than the femoral head radius. This is consistent with the geometrical constraint of the anatomical position and the direction of loading. It has been shown that the radius of the femoral head has the most significant effect on the maximum contact pressure for these closely conforming contacts where the contact half width is close to the femoral head radius. The effect of the elastic modulus and the thickness of UHMWPE is relatively small under these contact conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7952678     DOI: 10.1016/1350-4533(90)90006-t

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  The influence of stress conditions on the wear of UHMWPE for total joint replacements.

Authors:  P S Barbour; D C Barton; J Fisher
Journal:  J Mater Sci Mater Med       Date:  1997-10       Impact factor: 3.896

2.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

3.  The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.

Authors:  Rami K Korhonen; Arto Koistinen; Yrjö T Konttinen; Seppo S Santavirta; Reijo Lappalainen
Journal:  Biomed Eng Online       Date:  2005-05-17       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.