Volume spirometers need automated internal temperature sensors.

L R Johnson1, P L Enright, H T Voelker, D P Tashkin.   

Abstract

Spirometer temperature was measured automatically during all years of the Lung Health Study. Short- and long-term changes in temperature were analyzed for the 23 dry-rolling-seal volume spirometers used at the 10 clinical centers involved in the study. Within-test-session spirometer temperature increased a mean of 0.3 degrees C, and as much as 3.0 degrees C during methacholine challenge testing. The maximal change in spirometer temperature during a test day exceeded 4 degrees C more than 5% of the time. Month-to-month changes of more than 15 degrees C were not uncommon. If ambient temperature had been assumed to apply to all maneuvers and used for BTPS corrections, FEV1, and FVC measurement errors of up to 6% would have occurred. When using volume spirometers, the temperature of air inside the spirometer should be measured accurately during each breathing maneuver.

Entities:  

Mesh:

Year:  1994        PMID: 7952617     DOI: 10.1164/ajrccm.150.6.7952617

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  5 in total

1.  Reproducibility and validity of a handheld spirometer.

Authors:  R Graham Barr; Kimberly J Stemple; Sonia Mesia-Vela; Robert C Basner; Susan J Derk; Paul K Henneberger; Donald K Milton; Brenda Taveras
Journal:  Respir Care       Date:  2008-04       Impact factor: 2.258

2.  Acute effects of ozone on pulmonary function of cyclists receiving antioxidant supplements.

Authors:  L Grievink; S M Jansen; P van't Veer; B Brunekreef
Journal:  Occup Environ Med       Date:  1998-01       Impact factor: 4.402

3.  Calibrating the calibrators.

Authors:  P S Burge
Journal:  Thorax       Date:  1996-10       Impact factor: 9.139

4.  Lung function testing: methods and reference values for forced expiratory volume (FEV1) and transfer factor (TL).

Authors:  J E Cotes; D J Chinn; J W Reed
Journal:  Occup Environ Med       Date:  1997-07       Impact factor: 4.402

5.  Standardization of Spirometry 2019 Update. An Official American Thoracic Society and European Respiratory Society Technical Statement.

Authors:  Brian L Graham; Irene Steenbruggen; Martin R Miller; Igor Z Barjaktarevic; Brendan G Cooper; Graham L Hall; Teal S Hallstrand; David A Kaminsky; Kevin McCarthy; Meredith C McCormack; Cristine E Oropez; Margaret Rosenfeld; Sanja Stanojevic; Maureen P Swanney; Bruce R Thompson
Journal:  Am J Respir Crit Care Med       Date:  2019-10-15       Impact factor: 21.405

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.