Literature DB >> 7952613

Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation.

Y Imai1, T Kawano, K Miyasaka, M Takata, T Imai, K Okuyama.   

Abstract

Inflammatory chemical mediators, platelet-activating factor (PAF), thromboxane (TX) B2, and 6-keto-prostaglandin (PG)F1 alpha, were extracted from lung lavage fluid after conventional mechanical ventilation (CMV) and high frequency oscillatory ventilation (HFOV) to clarify the relation between mode of ventilation and lung injury in surfactant-depleted rabbit lungs. Anesthetized adult rabbits were tracheostomized, and surfactant depletion was induced by repeated saline lavage. Lung lavage for measurement of mediators was performed after 4 h of CMV at an FIO2 of 1.0 and a mean airway pressure of 15 cm H2O or HFOV (15 Hz) at an FIO2 of 1.0 or 0.21 and a mean airway pressure of 15 cm H2O. The number of total cells and polymorphonuclear leukocytes (PMN) and the levels of PAF, TXB2, and 6-keto-PGF1 alpha were measured by radioimmunoassay. Total respiratory compliance (Crs) was measured by the passive flow-volume curve method. The numbers of PMN, and the levels of PAF and TXB2 in lung lavage fluid were significantly greater during CMV than during HFOV. HFOV resulted in decreased production of PAF and TXB2 in a surfactant-depleted rabbit lung. Crs was significantly less during CMV than during HFOV. These results suggest that HFOV could prevent the release of such inflammatory chemical mediators and result in less lung injury than CMV.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7952613     DOI: 10.1164/ajrccm.150.6.7952613

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  23 in total

1.  Ventilator-induced lung injury.

Authors:  F B Plötz
Journal:  Intensive Care Med       Date:  2001-02       Impact factor: 17.440

Review 2.  The pulmonary physician in critical care * 7: ventilator induced lung injury.

Authors:  T Whitehead; A S Slutsky
Journal:  Thorax       Date:  2002-07       Impact factor: 9.139

3.  Bactericidal function of alveolar macrophages in mechanically ventilated rabbits.

Authors:  Nina G Hall; Yuliang Liu; Judy M Hickman-Davis; Glenda C Davis; Carpantato Myles; Eric J Andrews; Sadis Matalon; John D Lang
Journal:  Am J Respir Cell Mol Biol       Date:  2006-02-10       Impact factor: 6.914

4.  Effects of high-frequency oscillatory ventilation on oleic acid-induced lung injury in sheep.

Authors:  Rikimaru Nakagawa; Tomonobu Koizumi; Koichi Ono; Sumiko Yoshikawa; Kenji Tsushima; Tetsutarou Otagiri
Journal:  Lung       Date:  2008-06-26       Impact factor: 2.584

5.  High-frequency oscillatory ventilation reduces lung inflammation: a large-animal 24-h model of respiratory distress.

Authors:  Ralf M Muellenbach; Markus Kredel; Harun M Said; Bernd Klosterhalfen; Bernd Zollhoefer; Christian Wunder; Andreas Redel; Michael Schmidt; Norbert Roewer; Jörg Brederlau
Journal:  Intensive Care Med       Date:  2007-06-12       Impact factor: 17.440

6.  Different mechanism of LPS-induced calcium increase in human lung epithelial cell and microvascular endothelial cell: a cell culture study in a model for ARDS.

Authors:  Kejing Zhang; Ping Wang; Shuaishuai Huang; Xue Wang; Taohong Li; Yuhong Jin; Michael Hehir; Chiyi Xu
Journal:  Mol Biol Rep       Date:  2014-03-01       Impact factor: 2.316

Review 7.  Is ventilator-induced lung injury a promoter of multiple organ failure in adult respiratory distress syndrome? The effect of permissive hypercapnia on oxygenation and outcome.

Authors:  Keith G Hickling
Journal:  J Anesth       Date:  1997-03       Impact factor: 2.078

8.  Comparison of acid-induced inflammatory responses in the rat lung during high frequency oscillatory and conventional mechanical ventilation.

Authors:  Ming-Yuan Jian; Tomonobu Koizumi; Toshiki Yokoyama; Kenji Tsushima; Keishi Kubo
Journal:  Inflamm Res       Date:  2010-04-28       Impact factor: 4.575

9.  Arteriovenous CO2 removal improves survival compared to high frequency percussive and low tidal volume ventilation in a smoke/burn sheep acute respiratory distress syndrome model.

Authors:  Frank C Schmalstieg; Susan E Keeney; Helen E Rudloff; Kimberly H Palkowetz; Manuel Cevallos; Xiaoquin Zhou; Robert A Cox; Hal K Hawkins; Daniel L Traber; Joseph B Zwischenberger
Journal:  Ann Surg       Date:  2007-09       Impact factor: 12.969

Review 10.  Ventilator-induced lung injury and multiple system organ failure: a critical review of facts and hypotheses.

Authors:  Frans B Plötz; Arthur S Slutsky; Adrianus J van Vught; Cobi J Heijnen
Journal:  Intensive Care Med       Date:  2004-06-24       Impact factor: 17.440

View more