Literature DB >> 7952558

Detection of expiratory flow limitation during mechanical ventilation.

P Valta1, C Corbeil, A Lavoie, R Campodonico, N Koulouris, M Chassé, J Braidy, J Milic-Emili.   

Abstract

Two new methods, application of negative pressure at the airway opening during expiration (NEP) and reduction of flow resistance by bypassing the expiratory line of the ventilator by exhaling into the atmosphere (ATM), were used to detect expiratory flow limitation in 12 semirecumbent (45 degree) mechanically ventilated patients, seven with chronic airway obstruction (CAO). An increase of expiratory flow with NEP or ATM, relative to the preceding control breath, was taken as indicating absence of expiratory flow limitation. By contrast, the portion of the tidal expiration over which there was no change in flow with NEP or ATM was considered as flow-limited. With NEP, nine patients exhibited flow limitation, six (all with CAO) were flow-limited over most of the tidal expiration (> 70% VT), and three at < 60% VT. Although the results with NEP and ATM were in general in good agreement, in the three non-flow-limited patients the ATM method gave erroneous results. Six patients were also studied supine, including two who were not flow-limited when semirecumbent: both became flow-limited when supine. We conclude that NEP provides a simple method to detect flow limitation in mechanically ventilated patients. The supine position enhances flow limitation.

Entities:  

Mesh:

Year:  1994        PMID: 7952558     DOI: 10.1164/ajrccm.150.5.7952558

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  18 in total

1.  The semi-seated position slightly reduces the effort to breathe during difficult weaning.

Authors:  N Deye; F Lellouche; S M Maggiore; S Taillé; A Demoule; E L'Her; F Galia; A Harf; J Mancebo; L Brochard
Journal:  Intensive Care Med       Date:  2012-10-24       Impact factor: 17.440

2.  Paradoxical responses to positive end-expiratory pressure in patients with airway obstruction during controlled ventilation.

Authors:  Maria Paula Caramez; Joao B Borges; Mauro R Tucci; Valdelis N Okamoto; Carlos R R Carvalho; Robert M Kacmarek; Atul Malhotra; Irineu Tadeu Velasco; Marcelo B P Amato
Journal:  Crit Care Med       Date:  2005-07       Impact factor: 7.598

3.  Volume effect and exertional dyspnoea after bronchodilator in patients with COPD with and without expiratory flow limitation at rest.

Authors:  E Boni; L Corda; D Franchini; P Chiroli; G P Damiani; L Pini; V Grassi; C Tantucci
Journal:  Thorax       Date:  2002-06       Impact factor: 9.139

Review 4.  Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

Authors:  R Dueck
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

Review 5.  Monitoring ventilator weaning--predictors of success.

Authors:  L Weavind; A D Shaw; T W Feeley
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

6.  Upper Airway Collapsibility Assessed by Negative Expiratory Pressure while Awake is Associated with Upper Airway Anatomy.

Authors:  Raquel P Hirata; Fabiola Schorr; Fabiane Kayamori; Henrique Takachi Moriya; Salvatore Romano; Giuseppe Insalaco; Eloisa M Gebrim; Luis Vicente Franco de Oliveira; Pedro R Genta; Geraldo Lorenzi-Filho
Journal:  J Clin Sleep Med       Date:  2016-10-15       Impact factor: 4.062

7.  Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease.

Authors:  Eumorfia Kondili; Christina Alexopoulou; George Prinianakis; Nectaria Xirouchaki; Dimitris Georgopoulos
Journal:  Intensive Care Med       Date:  2004-03-31       Impact factor: 17.440

8.  Negative expiratory pressure (NEP) parameters can predict obstructive sleep apnea syndrome in snoring patients.

Authors:  Sonia Rouatbi; Zouhair Tabka; Mohamed Dogui; Ahmed Abdelghani; Hervé Guénard
Journal:  Lung       Date:  2008-10-16       Impact factor: 2.584

9.  Respiratory mechanics during exercise in endurance-trained men and women.

Authors:  Jordan A Guenette; Jonathan D Witt; Donald C McKenzie; Jeremy D Road; A William Sheel
Journal:  J Physiol       Date:  2007-04-05       Impact factor: 5.182

Review 10.  Hyperinflation and its management in COPD.

Authors:  Luis Puente-Maestu; William W Stringer
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2006
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.