Literature DB >> 7951775

A biological monitoring assessment of exposure to methylene dianiline in manufacturers and users.

J Cocker1, B P Nutley, H K Wilson.   

Abstract

This paper describes a cross sectional study in which biological monitoring was used to assess exposure to methylene dianiline (MDA) in a selection of United Kingdom industries that manufacture or use MDA. Samples of urine were collected from 411 workers, representing 45 factories engaged in various activities. All urine samples were analysed for MDA and its acetyl metabolites and results are reported as total MDA. In this study, 91% of postshift urine samples and 88% of preshift samples had less than 50 nmol MDA/mmol creatinine. Some evidence was obtained which showed that when exposure to MDA was through inhalation (as solid material or contaminated dust), postshift urine samples had higher MDA concentrations than samples taken preshift the next day. When exposure was most likely to be through the dermal route, urine samples taken preshift next day tended to have higher MDA concentrations than urine samples collected immediately postshift on the day of exposure. Therefore a biological monitoring sampling strategy for MDA must take account of the route of entry into the body. If exposure is likely to be via inhalation, postshift samples should be collected and if exposure is likely via the skin, preshift samples next day are more appropriate. The results show that in most factories, regardless of the route of exposure, it is possible to keep urinary MDA concentrations below 50 nmol/mmol creatinine. In the absence of a health based or hygiene based standard, the use of a "yardstick" as a target to aim for, which has been derived from good working practice across the industry, may be a useful way of helping to control exposure.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7951775      PMCID: PMC1128030          DOI: 10.1136/oem.51.8.519

Source DB:  PubMed          Journal:  Occup Environ Med        ISSN: 1351-0711            Impact factor:   4.402


  4 in total

1.  Genotoxicity of epoxy resin hardeners in the hepatocyte primary culture/DNA repair test.

Authors:  H Mori; N Yoshimi; S Sugie; H Iwata; K Kawai; N Mashizu; H Shimizu
Journal:  Mutat Res       Date:  1988-04       Impact factor: 2.433

2.  Towards a biological monitoring strategy for toluene.

Authors:  L Campbell; D M Marsh; H K Wilson
Journal:  Ann Occup Hyg       Date:  1987

3.  Mutagenicity of 4,4'-methylenedianiline derivatives in the Salmonella histidine reversion assay.

Authors:  T K Rao; G F Dorsey; B E Allen; J L Epler
Journal:  Arch Toxicol       Date:  1982-03       Impact factor: 5.153

4.  Assessment of occupational exposure to 4,4'-diaminodiphenylmethane (methylene dianiline) by gas chromatography-mass spectrometry analysis of urine.

Authors:  J Cocker; W Gristwood; H K Wilson
Journal:  Br J Ind Med       Date:  1986-09
  4 in total
  2 in total

1.  Characterization of biliary conjugates of 4,4'-methylenedianiline in male versus female rats.

Authors:  Kan Chen; Richard B Cole; Vicente Santa Cruz; Ernest W Blakeney; Mary F Kanz; Tammy R Dugas
Journal:  Toxicol Appl Pharmacol       Date:  2008-07-01       Impact factor: 4.219

2.  Proposal for the assessment to quantitative dermal exposure limits in occupational environments: Part 2. Feasibility study for application in an exposure scenario for MDA by two different dermal exposure sampling methods.

Authors:  D H Brouwer; L Hoogendoorn; P M Bos; P J Boogaard; J J van Hemmen
Journal:  Occup Environ Med       Date:  1998-12       Impact factor: 4.402

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.