Transesophageal pulsed-Doppler echocardiographic evaluation of transmitral and pulmonary venous flow during ventilation with positive end-expiratory pressure.

H W Meijburg1, C A Visser, H Wesenhagen, P W Westerhof, E O Robles de Medina.   

Abstract

During mechanical ventilation with high levels of positive end-expiratory pressure (PEEP) several hemodynamic changes occur, the mechanism of which has been the subject of various previous studies. The effects of increasing levels of PEEP during mechanical ventilation were measured on left atrial and left ventricular filling dynamics, as assessed by pulmonary venous and transmitral flow velocities, respectively. Using transesophageal echocardiography in 12 patients, Doppler flow velocities of pulmonary venous and transmitral flow were studied at baseline (0 cmH2O PEEP) and at 5, 10, 15, and 20 cm H2O with 10-minute intervals, and once more after removal of PEEP. In 2 of the 12 patients, PEEP could not be increased beyond 15 cmH2O, because cardiac index fell below 2.0 L/min/m2. Pulmonary venous flow velocity and velocity time integral during systole significantly decreased from 48 +/- 7 cm/s and 10.3 +/- 2.2 cm at baseline to 35 +/- 6 cm/s and 5.7 +/- 2.5 cm at 20 cmH2O PEEP, respectively (P < 0.01). In contrast, early and late diastolic velocities and velocity time integrals did not change. In regard to transmitral flow, both early and late diastolic velocities significantly decreased from 51 +/- 7 cm/s and 50 +/- 9 cm/s at baseline to 38 +/- 7 cm/s at 20 cmH2O PEEP, respectively (P < 0.01). Early and late diastolic velocity time integrals decreased from 6.1 +/- 1.8 cm and 4.7 +/- 1.0 cm to 4.5 +/- 1.0 cm (NS) and 3.4 +/- 0.7 cm (P < 0.05), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7948792     DOI: 10.1016/1053-0770(94)90275-5

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

1.  Acute effects of positive end-expiratory pressure on left ventricle diastolic function in healthy subjects.

Authors:  Alberto Maestroni; Stefano Aliberti; Omar Amir; Giuseppe Milani; Anna Maria Brambilla; Federico Piffer; Francesca Tardini; Roberto Cosentini
Journal:  Intern Emerg Med       Date:  2009-04-29       Impact factor: 3.397

2.  Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects.

Authors:  Peter Juhl-Olsen; Christian Alcaraz Frederiksen; Johan Fridolf Hermansen; Carl-Johan Jakobsen; Erik Sloth
Journal:  Crit Care Res Pract       Date:  2012-09-25