Literature DB >> 7944697

Intraoperative assessment of coronary artery bypass grafts using a pulsed Doppler flowmeter.

Y A Louagie1, J P Haxhe, J Jamart, M Buche, J C Schoevaerdts.   

Abstract

A pulsed Doppler flowmeter was used in a series of 352 consecutive patients undergoing isolated coronary artery bypass grafting. Doppler flow measurements were available on 909 single terminolateral bypass grafts (327 internal mammary arteries and 582 saphenous veins) and 58 sequential bypass grafts anastomosed to combinations of arteries. Flow (mL/min) categorized as a function of the recipient artery was distributed as follows: left anterior descending coronary artery, 69.9 +/- 2.5; right coronary artery, 68.0 +/- 5.0; diagonals, 61.0 +/- 4.1; obtuse marginals, 55.9 +/- 2.2; and posterior descending coronary artery, 53.3 +/- 3.0 (p < 0.001). Graft outflow obstruction resulting from torsion of the graft pedicle or anastomotic stricture was identified in 7 patients (2%). After graft revision, flow increased from 9 +/- 4 mL/min to 69 +/- 13 mL/min (p = 0.023), and velocity rose from 4.6 +/- 1.1 cm/s to 18.1 +/- 2.4 cm/s (p = 0.009). In conclusion, the system was adequate for operative use and allowed identification and correction of technical errors.

Entities:  

Mesh:

Year:  1994        PMID: 7944697     DOI: 10.1016/0003-4975(94)90738-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Adaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand.

Authors:  O Gurné; P Chenu; M Buche; Y Louagie; P Eucher; B Marchandise; E Rombaut; D Blommaert; E Schroeder
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

2.  Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency.

Authors:  Atsutoshi Hatada; Yoshitaka Okamura; Masahiro Kaneko; Takahiro Hisaoka; Shuji Yamamoto; Takeshi Hiramatsu; Yoshiharu Nishimura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-01-12

3.  Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery.

Authors:  Ilhan Sanisoglu; Mustafa Guden; Cem Balci; Ertan Sagbas; Cihan Duran; Belhhan Akpinar
Journal:  Tex Heart Inst J       Date:  2003

4.  Newly Developed Graft Failure Detected Using Computed Tomography Within 1 Year After Coronary Artery Bypass Grafting Surgery: One Single-Center Experience.

Authors:  Zhaoshui Li; Youjin Qiao; Wei Sheng; Yifan Chi
Journal:  Front Cardiovasc Med       Date:  2022-01-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.