Literature DB >> 7943790

Comparison of the force required for dural puncture with different spinal needles and subsequent leakage of cerebrospinal fluid.

J L Westbrook1, D R Uncles, B T Sitzman, L E Carrie.   

Abstract

An in vitro model was used to determine the force required to pierce bovine dura with a range of new spinal needles and to measure the subsequent leakage rate of cerebrospinal fluid (CSF). A significantly greater force was required to pierce the dura with pencil-point style needles compared to Quincke needles of the same size. Quincke needles caused a greater loss of CSF than their pencil-point equivalents. The results suggest that there is not likely to be a significant reduction in postdural puncture headache (PDPH) using a 27-gauge pencil-point needle compared to a 25-gauge needle that may be easier to use. Different makes of the same design and gauge of needle showed significant differences in the amount of CSF leakage, which may influence the clinician's choice of needle.

Entities:  

Mesh:

Year:  1994        PMID: 7943790     DOI: 10.1213/00000539-199410000-00026

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Comparison of 26-gauge Atraucan and 25-gauge Whitacre needles: insertion characteristics and complications.

Authors:  S K Sharma; D R Gambling; G P Joshi; J E Sidawi; E R Herrera
Journal:  Can J Anaesth       Date:  1995-08       Impact factor: 5.063

Review 2.  Post-dural puncture headaches in children. A literature review.

Authors:  Elke Janssens; Peter Aerssens; Phillipe Alliët; Phillipe Gillis; Marc Raes
Journal:  Eur J Pediatr       Date:  2003-01-15       Impact factor: 3.183

3.  Complications associated with intrathecal morphine in spine surgery: a retrospective study.

Authors:  Arif Pendi; Yu-Po Lee; Saif Al-Deen B Farhan; Frank L Acosta; S Samuel Bederman; Ronald Sahyouni; Elias R Gerrick; Nitin N Bhatia
Journal:  J Spine Surg       Date:  2018-06

Review 4.  Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

Authors:  Chongjun Yang; Yu Xie; Shuang Liu; Dong Sun
Journal:  Sensors (Basel)       Date:  2018-02-12       Impact factor: 3.576

5.  The Effects of the Quincke Spinal Needle Bevel Insertion on Postdural Puncture Headache and Hemodynamics in Obstetric Patients.

Authors:  Fikret Salik; Ebru Tarikçi Kiliç; Hakan Akelma; Abdülmenap Güzel
Journal:  Anesth Essays Res       Date:  2018 Jul-Sep
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.