Literature DB >> 7943782

Prospective comparison of use of the laryngeal mask and endotracheal tube for ambulatory surgery.

R C Cork1, R M Depa, J R Standen.   

Abstract

We examined the response to the laryngeal mask (LM) compared to the endotracheal tube (ETT) in patients undergoing ambulatory anesthesia. The differences in management by the anesthesiologists for these two airways were also examined. Peripheral orthopedic procedures were studied in 44 outpatients randomized to receive a LM or ETT, and either spontaneous or controlled ventilation. Anesthesia was induced with propofol and succinylcholine intravenously (i.v.) and maintained with N2O and isoflurane. Anesthesiologists were allowed to determine ventilatory variables and anesthetic concentration. Hemodynamic and ventilatory measurements were made during the anesthesia. Barium sulfate was poured into the oropharynx after the airway was secure. Fiberoptic examination through the LM was performed at the beginning and at the end of the administration of each anesthetic. Radiographs were taken at the end of the anesthetic administration before LM or ETT removal to look for barium in the trachea. After airway removal, presence of blood on the airway, sore throat, coughing, nausea, vomiting, shivering, and amount of morphine demanded during recovery were noted. No barium in the trachea or bronchial tree was seen in any of the radiographs. The ETT was associated with greater hemodynamic response not only to airway placement (P < 0.05), but also to surgical incision (P < 0.05) and airway removal (P < 0.05). Spontaneous or controlled ventilation favored neither airway, although the ETT was associated with increased work of inspiration with controlled ventilation (P < 0.05). Anesthesiologists tended to elect smaller tidal volumes, faster ventilation rates, and lower anesthetic concentrations for patients with the LM (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7943782     DOI: 10.1213/00000539-199410000-00018

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  11 in total

1.  Supraglottic Airway Use for Transfemoral-Transcatheter Aortic Valve Replacement.

Authors:  Shara S Azad; Frederick C Cobey; Lori Lyn Price; Roman Schumann; Alexander D Shapeton
Journal:  J Cardiothorac Vasc Anesth       Date:  2020-05-15       Impact factor: 2.628

2.  The advantages of the LMA over the tracheal tube or facemask: a meta-analysis.

Authors:  J Brimacombe
Journal:  Can J Anaesth       Date:  1995-11       Impact factor: 5.063

3.  Comparison between the Baska Mask® and I-Gel for Minor Surgical Procedures Under General Anaesthesia.

Authors:  Roopa Sachidananda; Safiya I Shaikh; Milon Vasant Mitragotri; Vikas Joshi; Dharmesh Arvind Ladhad; Marutheesh Mallappa; Vikram Kemmannu Bhat
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-02-01

4.  Clinical Comparison of I-Gel Supraglottic Airway Device and Cuffed Endotracheal Tube for Pressure-Controlled Ventilation During Routine Surgical Procedures.

Authors:  Ankur Dhanda; Shalendra Singh; Anju R Bhalotra; Siddharth Chavali
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-10-01

5.  PLMA vs. I-gel: A Comparative Evaluation of Respiratory Mechanics in Laparoscopic Cholecystectomy.

Authors:  Bimla Sharma; Raminder Sehgal; Chand Sahai; Jayashree Sood
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2010-10

6.  A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure.

Authors:  Mostafa Somri; Sonia Vaida; Gustavo Garcia Fornari; Gabriela Renee Mendoza; Pedro Charco-Mora; Naser Hawash; Ibrahim Matter; Forat Swaid; Luis Gaitini
Journal:  BMC Anesthesiol       Date:  2016-10-06       Impact factor: 2.217

7.  Comparison of I-gel versus Endotracheal Tube in Patients Undergoing Elective Cesarean Section: A Prospective Randomized Control Study.

Authors:  Manohar Panneer; Saravana Babu; Prakash Murugaiyan
Journal:  Anesth Essays Res       Date:  2017 Oct-Dec

8.  I-Gel is a suitable alternative to endotracheal tubes in the laparoscopic pneumoperitoneum and trendelenburg position.

Authors:  Chih-Jun Lai; Chih-Min Liu; Chun-Yu Wu; Feng-Fang Tsai; Ping-Huei Tseng; Shou-Zen Fan
Journal:  BMC Anesthesiol       Date:  2017-01-06       Impact factor: 2.217

9.  Comparison of I-gel with proseal LMA in adult patients undergoing elective surgical procedures under general anesthesia without paralysis: A prospective randomized study.

Authors:  Gurudas Kini; Gopalkrishna Mettinadka Devanna; Koteswara Rao Mukkapati; Souvik Chaudhuri; Daniel Thomas
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-04

10.  A randomized control study comparing the pharyngolaryngeal morbidity of laryngeal mask airway versus endotracheal tube.

Authors:  A Venugopal; Ron Mathew Jacob; Rachel Cherian Koshy
Journal:  Anesth Essays Res       Date:  2016 May-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.