Literature DB >> 7942477

Self-expandable and highly flexible nitinol stent: immediate and long-term results in dogs.

E Grenadier1, R Shofti, M Beyar, H Lichtig, D Mordechowitz, O Globerman, W Markiewicz, R Beyar.   

Abstract

We sought to investigate the acute and long-term patency rates and the histologic response of coronary arteries to a self-expandable nitinol coil stent. Twenty-two stents were implanted. Angiographic patency was demonstrated acutely in all but one dog, in which the stent was released in a small branch (1 mm); mismatch in stent-to-artery diameters resulted in vessel closure. Two dogs died from anesthesia overdose and two from bleeding within 24 hours. All dogs were treated with aspirin (80 mg/day) and warfarin (2.5 mg/day) for up to 1 month. Sixteen dogs were monitored for 1 to 2 weeks, 1 month, 3 months, 6 months, and 1 year and underwent subsequent angiography and histopathologic examination. Angiographic artery dimensions measured immediately after stent implantation (2.72 +/- 0.4 mm) did not differ from those noted at follow-up (2.68 +/- 0.44 mm, p not significant). Histologic examination showed outward stent pressure compressing the internal elastic membrane and media in most cases. Intimal hyperplasia started at 2 weeks and was most apparent at 3 and 6 months. Mean intimal thickness was 30.7 +/- 10.9 mu, 141.8 +/- 105.4 mu, 227.1 +/- 104.1 mu, 211.8 +/- 99.1 mu, and 170.1 +/- 42.7 mu at 1 to 2 weeks and 1, 3, 6 and 12 months, respectively. Therefore the nitinol self-expandable stent provokes a moderate cellular proliferative response that reaches its maximum in 3 to 6 months without further progression.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7942477     DOI: 10.1016/0002-8703(94)90582-7

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  The acute effect of stenting with the nitinol self-expanding coil stent: preliminary experience.

Authors:  A Roguin; R Beyar
Journal:  Int J Card Imaging       Date:  1997-12

2.  Angiographically confirmed stent over expansion in the internal carotid artery during stenting: incidence, predictors, and outcomes.

Authors:  Masanori Tsutsumi; Hiroshi Aikawa; Kouhei Nii; Housei Etou; Kimiya Sakamoto; Hidenori Yoshida; Yoshihisa Matsumoto; Shuko Hamaguchi; Kiyoshi Kazekawa
Journal:  Neuroradiology       Date:  2011-07-06       Impact factor: 2.804

3.  Effect of Stent Radial Force on Stress Pattern After Deployment: A Finite Element Study.

Authors:  Alessandro Borghi; Olive Murphy; Reza Bahmanyar; Chris McLeod
Journal:  J Mater Eng Perform       Date:  2014-02-26       Impact factor: 1.819

  3 in total