Comparison of transit-time and Doppler ultrasound methods for measurement of flow in aortocoronary bypass grafts during cardiac surgery.

K Matre1, S Birkeland, I Hessevik, L Segadal.   

Abstract

To evaluate the accuracy of flow measurements in aortocoronary bypass grafts with the ultrasound transit-time method, an in vitro and in vivo comparison was carried out. The in vitro comparison with evaluation against both true flow and the ultrasound Doppler method, was carried out with a fresh saphenous vein mounted in a pulsatile flow rig. The two flow probes were placed on the graft 4-5 cm apart to avoid acoustic interference, and blood was pumped through the system at different flow rates. The comparison between the methods showed excellent agreement with a linear correlation coefficient of 0.996, and a mean error of -2.9 ml/min with limits of agreement +/- 13.1 ml/min (+/- 2 SD = 95% of measured differences between these limits). However, against true flow, both methods overestimated flow slightly with mean error 4.4 and 7.3 ml/min for the transit-time and Doppler, respectively. Both methods showed excellent correlation with true flow (correlation coefficient 0.998 for the transit-time and 0.997 for the Doppler method). The in vivo accuracy was evaluated by comparison of the two methods in 9 patients. The two probes were placed on the same saphenous vein grafts 4-5 cm apart, and a total of 34 measurements in 17 grafts were carried out including measurements at baseline and after papaverine injection. The correlation coefficient was 0.990 and linear regression analysis gave the equation: Transit-time flow = 1.00 x Doppler flow + 1.3. In terms of flow, the mean error was 1.5 ml with limits of agreement +/- 17.2 ml.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7940488     DOI: 10.1055/s-2007-1016481

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  2 in total

1.  Real-time assessment of cardiac perfusion, coronary angiography, and acute intravascular thrombi using dual-channel near-infrared fluorescence imaging.

Authors:  Eiichi Tanaka; Frederick Y Chen; Robert Flaumenhaft; Gwenda J Graham; Rita G Laurence; John V Frangioni
Journal:  J Thorac Cardiovasc Surg       Date:  2009-07       Impact factor: 5.209

2.  Patient and haemodynamic factors affecting intraoperative graft flow during coronary artery bypass grafting: an observational pilot study.

Authors:  Sang-Wook Lee; Jun-Young Jo; Wook-Jong Kim; Dae-Kee Choi; In-Cheol Choi
Journal:  Sci Rep       Date:  2020-07-31       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.