A rhythmic electrical signal is present in the human small intestine and can be recorded using surface electrodes. Surface electrical recordings of the small intestine contain severe interference that obscures the electrical signal of the small intestine. An adaptive system is proposed in the paper for the enhancement of the small-intestinal signal. To obtain better performance, adaptive signal enhancement is performed in the transform domain using a discrete cosine transform (DCT). A fast recursive algorithm is developed for the calculation of running DCT. The computational complexity of the proposed recursive algorithm is only 2/N (N = length of the adaptive filter) of the direct calculation of the running DCT. A series of simulations are conducted to investigate the performance of the proposed transform-domain adaptive filtering using DCT in comparison with time-domain adaptive filtering and with transform-domain adaptive filtering using a discrete Fourier transform (DFT). The parameters of the proposed adaptive system are optimised, and their effects on system performance are investigated. The application of the proposed method for the enhancement of the small-intestinal signal is presented and discussed.

Entities:  

Mesh:

Year:  1994        PMID: 7934257     DOI: 10.1007/bf02512529

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  Adaptive cancellation technique in processing myoelectric activity of respiratory muscles.

Authors:  P Akkiraju; D C Reddy
Journal:  IEEE Trans Biomed Eng       Date:  1992-06       Impact factor: 4.538

2.  Chronic in situ studies of the electrical activity of the small intestine.

Authors:  C E Bunker; L P Johnson; T S Nelsen
Journal:  Arch Surg       Date:  1967-08

3.  Intestinal smooth muscle electrical potentials recorded from surface electrodes.

Authors:  B H Brown; R H Smallwood; H L Duthie; C J Stoddard
Journal:  Med Biol Eng       Date:  1975-01

Review 4.  Electrogastrography: measurement, analysis and prospective applications.

Authors:  J Chen; R W McCallum
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

5.  Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection.

Authors:  N V Thakor; Y S Zhu
Journal:  IEEE Trans Biomed Eng       Date:  1991-08       Impact factor: 4.538

6.  Multichannel adaptive enhancement of the electrogastrogram.

Authors:  J D Chen; J Vandewalle; W Sansen; G Vantrappen; J Janssens
Journal:  IEEE Trans Biomed Eng       Date:  1990-03       Impact factor: 4.538

7.  Adaptive method for cancellation of respiratory artefact in electrogastric measurements.

Authors:  J Chen; J Vandewalle; W Sansen; G Vantrappen; J Janssens
Journal:  Med Biol Eng Comput       Date:  1989-01       Impact factor: 2.602

8.  Adaptive filtering of evoked potentials.

Authors:  N V Thakor
Journal:  IEEE Trans Biomed Eng       Date:  1987-01       Impact factor: 4.538

9.  Spectral analysis of episodic rhythmic variations in the cutaneous electrogastrogram.

Authors:  J D Chen; W R Stewart; R W McCallum
Journal:  IEEE Trans Biomed Eng       Date:  1993-02       Impact factor: 4.538

10.  Measurement of electrical activity of the human small intestine using surface electrodes.

Authors:  J D Chen; B D Schirmer; R W McCallum
Journal:  IEEE Trans Biomed Eng       Date:  1993-06       Impact factor: 4.538

View more
  6 in total

1.  Extraction of gastric slow waves from electrogastrograms: combining independent component analysis and adaptive signal enhancement.

Authors:  H Liang
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  Noninvasive biomagnetic detection of intestinal slow wave dysrhythmias in chronic mesenteric ischemia.

Authors:  S Somarajan; N D Muszynski; L K Cheng; L A Bradshaw; T C Naslund; W O Richards
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2015-04-30       Impact factor: 4.052

3.  Comparison of adaptive filtering in time-, transform- and frequency-domain: an electrogastrographic study.

Authors:  J D Chen; Z Lin
Journal:  Ann Biomed Eng       Date:  1994 Jul-Aug       Impact factor: 3.934

4.  Magnetoenterography for the Detection of Partial Mesenteric Ischemia.

Authors:  Suseela Somarajan; Nicole D Muszynski; Joseph D Olson; Leonard A Bradshaw; William O Richards
Journal:  J Surg Res       Date:  2019-02-20       Impact factor: 2.192

5.  Noninvasive biomagnetic detection of isolated ischemic bowel segments.

Authors:  Suseela Somarajan; Summer Cassilly; Chibuike Obioha; L A Bradshaw; William O Richards
Journal:  IEEE Trans Biomed Eng       Date:  2013-01-15       Impact factor: 4.538

6.  Empirical mode decomposition: a method to reduce low frequency interferences from surface electroenterogram.

Authors:  Y Ye; J Garcia-Casado; J L Martinez-de-Juan; J L Ponce
Journal:  Med Biol Eng Comput       Date:  2007-05-30       Impact factor: 3.079

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.